Fixed Nitrogen (N2) Gas Detector, 0 to 100% Vol

5 out of 5 based on 9 reviews | Write a review
$742.46
Buy nitrogen gas detector from high-quality manufacturer at good price. Measuring range 0-100% Vol, supports remote control, optional output signal 4-20mA and RS485, high accuracy 3% F.S, fast response within 10s. N2 gas detector for nitrogen concentration detecting and leak monitor, sound and light alarm, 24h online, real-time display, fixed mounting.
*
*
*
*
*
SKU: GD300-N2
30-day Returns
Free Shipping
Delivery date: 6-12 days

Excellent supplier nitrogen gas detector for sale. Working range 0 to 100% Vol, remote control with 4-20mA & RS485 output signal, supports sound and light alarm. Fixed N2 gas detector for nitrogen concentration detecting and leak monitor, high quality, low price.

Features

  • Nitrogen gas detector adopts high precision sensor for accurate gas leak detection.
  • Nitrogen gas detector is equipped with 3-wire system 4-20mA analog output, relay output, RS485 output (optional).
  • The N2 gas detector is compatible with various controlled alarms, PLC, DCS and other control system, and can be remote monitored.
  • Explosion-proof design, fast, relaible and stable.
  • Infrared ray controller can remote control the alarm point settings, zero calibration, and address modification.
  • Two-stage alarm with sound and light, and the alarm point is settable.
  • The nitrogen gas detector has self-calibration function, and three standard keys will be used to realize on-site maintenance.
  • The N2 gas detector can output one or two on-off signals, can drive ventilator, solenoid valve or other external devices.

Specification

Model GD300-N2
Detection Principle Electrochemistry
Gas Nitrogen (N2)
Note* 1. It is recommended that this N2 gas detector only detects a single Nitrogen environment or only N2 and O2 in the environment, as well as Nitrogen leakage in normal air. If you are monitoring other gases mixed with N2, please contact us before purchasing.
2. Nitrogen detectors cannot do zero point calibration in air, only do target calibration (the target concentration is the standard concentration value in clean air).
Range (Optional) 0-99.99% VOL, 0-100% VOL
Resolution 0.01%VOL (0-99.99%VOL), 0.1%VOL (0-100%VOL)
Calibration Kit Gas pressure regulator (calibration gas cylinder NOT included)
Accuracy ≤±3% F.S.
Response Time ≤10s
Repeatability ≤±1%
Recovery Time ≤10s
Linearity Error ≤±1%
Zero Shift ≤±1% (F.S./year)
Signal Output (Optional) 4-20mA and RS485
Relay output: one group of relay output (1NO+1NC, 24V 100mA) for one alarm (default), or two groups of relay output (2NO+2NC, 24V 100mA) for high/low alarm (optional).
Alarms Sound, light
Display High light nixie tube display
Installation Wall-mounted, piping type, flow-type (according to the detected environment)
Connection Power connection type: G1/2 male thread explosion-proof flexible pipe
Pipe-mounted type: M45*P2.0
Operating Time 24h
Explosion-proof Grade Ⅱ 2G Ex ia Ⅱ CT4 Ga
Protection Grade IP65
Certification CE, ATEX (Standard: EN IEC 60079-0:2018, EN 60079-1:2014)
Working Voltage 12-36V DC
Case Material Die-casting aluminum housing
Operating Temperature -20℃~50℃
Operating Humidity 0~95%RH (non-condensing)
Dimension 206*179*90mm
Weight ≤1.6kg
Accessories Power adapter: Input 100-240VAC 50/60Hz, Output 24VDC 1A (Optional USA plug, Europe plug or UK plug)

Note: To measure confined spaces such as pipelines, please contact us and inform the detailed conditions of use.

Fixed Nitrogen (N2) Gas Detector Dimension (Unit: mm)

Fixed gas detector with alarm dimension

***Other Common Gases and Ranges Available for Fixed Gas Detectors

Gas Type Measure Range Resolution
Ammonia (NH3) 0-50/100/200/500/1000/2000/5000ppm 0.01ppm/0.1ppm/1ppm
Benzene (C6H6) 0-1/10/50/100/200/1000/2000/5000/10000ppm 0.001ppm/0.01ppm/0.1ppm/1ppm
Carbon Dioxide (CO2) 0-1000/2000/5000/9999ppm, 0-2/5/10/20/25/30/50/100%VOL 0.1ppm/1ppm/0.001%VOL/0.01%VOL/0.1%VOL
Carbon Monoxide (CO) 0-10/20/50/100/500/1000/2000ppm 0.01ppm/0.1ppm/1ppm
Chlorine (Cl2) 0-5/10/20/50/100ppm 0.001ppm/0.01ppm/0.1ppm
Chlorine Dioxide (ClO2) 0-1/5/10/20/50/100ppm 0.001ppm/0.01ppm/0.1ppm
Combustible Gas (EX) 0-100%LEL 1%LEL
Ethylene (C2H4) 0-10/20/50/100/500/1000/2000ppm 0.01ppm/0.1ppm/1ppm
Formaldehyde (CH2O) 0-10/20/50/100/500/1000ppm 0.01ppm/0.1ppm/1ppm
Hydrocarbons (HC) 0-100%LEL 1%LEL
Hydrogen (H2) 0-10/20/500/1000/2000/5000/9999ppm, 0-2/4% VOL, 0-100% LEL 0.1ppm/1ppm/0.001%VOL/1%LEL
Hydrogen Chloride (HCL) 0-10/20/50/100/200ppm 0.01ppm/0.1ppm
Hydrogen Cyanide (HCN) 0-10/20/50/100ppm 0.01ppm/0.1ppm
Hydrogen Sulfide (H2S) 0-5/20/50/100/200ppm 0.001ppm/0.01ppm/0.1ppm
Methane (CH4) 0-50/100%VOL, 0-100%LEL 0.01%VOL/0.1%VOL/1%LEL
Nitric Oxide (NO) 0-1/5/10/20/50/100/250/500/1000ppm 0.001ppm/0.01ppm/0.1ppm/1ppm
Nitrogen (N2) 0-99.99/0-100%VOL 0.01%VOL/0.1%VOL
Nitrogen Dioxide (NO2) 0-1/5/10/20/50/100/500/1000ppm 0.001ppm/0.01ppm/0.1ppm/1ppm
Nitrogen Oxides (NOX) 0-1/5/10/20/50/100/250/500/1000ppm 0.001ppm/0.01ppm/0.1ppm/1ppm
Oxygen (O2) 0-25/30/100%VOL 0.01%VOL/0.1%VOL
Ozone (O3) 0-1/5/10/20/50/100ppm 0.001ppm/0.01ppm/0.1ppm
Phosphine (PH3) 0-10/20/50/100/500/1000/2000/3000ppm 0.01ppm/0.1ppm/1ppm
Sulfur Dioxide (SO2) 0-1/5/10/20/50/100/500/1000ppm 0.001ppm/0.01ppm/0.1ppm/1ppm
Volatile Organic Compounds (VOC) 0-1/5/10/20/50/100/200/500/1000/2000/5000/10000ppm 0.001ppm/0.01ppm/0.1ppm/1ppm

Note: Some common gases and the measuring ranges are listed in the above table. For more information, please feel free to contact us.

Details

Fixed Nitrogen (N2) Gas Detector Details

Tips: Maintenance of nitrogen gas detector

  1. Regularly calibrate, test and inspect the nitrogen gas detector. In general, the calibration frequency is once a year.
  2. As the most important part of nitrogen gas detector, the sensor should avoid exposure to the gas generated by inorganic solvents or organic solvents as much as possible. Especially for electrochemical sensors used to detect toxic and harmful gases, the evaporation or contamination of the electrolyte will cause the signal of the sensor to drop and shorten the service life of the N2 gas detector.
  3. When installing the nitrogen gas detector, please do not put it close to the wall, and reserve enough space around it for daily maintenance and troubleshooting.
  4. Ensure that the nitrogen gas detector is in a dry state to avoid affecting its detection accuracy and service life due to the humid environment.
  5. The entire outside of the nitrogen gas detector needs to be kept clean. You can wipe the surface with a soft damp cloth. Do not use a damp cloth dripping with water to prevent water droplets from accidentally splashing into the N2 gas detector.
  6. Dust cover of the sensor is for protection. In order to prevent the dust cover from being blocked by dust and affecting the use of sensor, it should be cleaned regularly.
Existing reviews of Fixed Nitrogen (N2) Gas Detector, 0 to 100% Vol
Fixed N2 Gas Detector
Can the N2 gas detector measure the N2 concentration in Natural Gas?
From: Jie | Date: 12/08/2024
Was this review helpful? Yes No (0/0)
ATO Responded
N2 gas detector cannot measure the N2 concentration in natural gas.
Inquiry on details
I am planning on using this in the pipe configuration and want to measure Nitrogen concentration in a mixture of Nitrogen and Oxygen gas. If the flow rate is only around 100 mL/min, will the results still be accurate? This is assuming the gas is near standard temperature and pressure.
From: Elena | Date: 13/06/2024
Was this review helpful? Yes No (0/0)
ATO Responded
The required flow rate of gas in the pipeline is 400~800ml/min.
100ml flow rate is too small and can Not be used normally.
Fixed Nitrogen (N2) Gas Detector
Can the sensor be placed in line tubing with pressurized gas? or is this for atmosphere detection only?  Or is there a way to mount the detection point in line with the gas flow?
From: calebs | Date: 28/11/2023
Was this review helpful? Yes No (0/0)
ATO Responded
In this case, you need to reduce the gas pressure in the pipeline to 1Bar±10% before it can be used normally, such as installing a pressure regulating device on the pipeline.
Load more reviews...
Write your review for Fixed Nitrogen (N2) Gas Detector, 0 to 100% Vol
  • Only registered users can write reviews
  • Bad
  • Excellent
Customers who bought this item also bought

Fixed Carbon Dioxide (CO2) Gas Detector, 0 to 9999 ppm

$757.85
SKU: GD300-CO2
Economical price fixed gas detector from ideal supplier, for carbon dioxide detection. Measuring range 0-1000/2000/5000/9999 ppm for selection, remote control output signal 4-20mA and RS485, monitor CO2 concentration and sound & light alarm, high accuracy 3% F.S, fast response within 10s, 24h work and real-time display.

Fixed Hydrogen (H2) Gas Detector, 0 to 1000/2000/5000 ppm

$634.77
SKU: GD300-H2
Affordable price hydrogen gas detector for sale. Optional measuring range 0-1000/2000/5000 ppm, max 10000 ppm, supports remote control with output signal 4-20mA and RS485, high accuracy 3% F.S. H2 gas leak detector for hydrogen concentration detecting with sound & light alarm, fixed design, compact structure.

Fixed Combustible Gas Detector, 0 to 100%LEL

$526.67
SKU: GD300-EX
Combustible gas detector is fixed to detect the flammable gas leakage and gives the alarm with sound and light. With real-time display and remote control, flammable gas detector is available with signal output 4-20mA and RS485, fast response and high accuracy.