    Fixed Carbon Dioxide (CO2) Gas Detector, 0 to 9999 ppm

    5 out of 5 based on 2 reviews | Write a review
    $757.85
    Economical price fixed gas detector from ideal supplier, for carbon dioxide detection. Measuring range 0-1000/2000/5000/9999 ppm for selection, remote control output signal 4-20mA and RS485, monitor CO2 concentration and sound & light alarm, high accuracy 3% F.S, fast response within 10s, 24h work and real-time display.
    *
    *
    *
    *
    *
    SKU: GD300-CO2
    30-day Returns
    Free Shipping
    Delivery date: 6-12 days

    Carbon dioxide gas detector provided by ATO manufacturer, reasonable price. Detecting range 0-1000/2000/5000/9999 ppm optional, output signal 4-20mA & RS485 for remote control. CO2 gas detector has fixed design, has sound and light alarm, real time display, 24 hours online for carbon dioxide leak monitor.

    Features

    • Carbon dioxide gas detector adopts high precision sensor for accurate gas leak detection.
    • Carbon dioxide gas detector is equipped with 3-wire system 4-20mA analog output, relay output, RS485 output (optional).
    • The CO2 gas detector is compatible with various controlled alarms, PLC, DCS and other control system, and can be remote monitored.
    • Explosion-proof design, fast, relaible and stable.
    • Infrared ray controller can remote control the alarm point settings, zero calibration, and address modification.
    • Two-stage alarm with sound and light, and the alarm point is settable.
    • The carbon dioxide gas detector has self-calibration function, and three standard keys will be used to realize on-site maintenance.
    • The CO2 gas detector can output one or two on-off signals, can drive ventilator, solenoid valve or other external devices.

    Specification

    Model GD300-CO2
    Detection Principle Infrared
    Gas Carbon Dioxide (CO2)
    Range (Optional) 0 to 1000ppm, 0 to 2000ppm, 0 to 5000ppm, 0 to 9999ppm, 0 to 2% VOL, 0 to 5% VOL, 0 to 10% VOL, 0 to 20% VOL, 0 to 25% VOL, 0 to 30% VOL, 0 to 50% VOL, 0 to 100% VOL
    Resolution 1ppm (0-1000/2000/5000/9999ppm), 0.001% VOL (0-2% VOL, 0-5% VOL), 0.01% VOL (0-10% VOL, 0-20% VOL, 0-25% VOL, 0-30% VOL, 0-50% VOL), 0.1% VOL (0-100% VOL)
    Accuracy ≤±3% F.S.
    Response Time ≤10s
    Repeatability ≤±1%
    Recovery Time ≤10s
    Linearity Error ≤±1%
    Zero Shift ≤±1% (F.S./year)
    Signal Output (Optional) 4-20mA ans RS485
    Relay output: one group of relay output (1NO+1NC, 24V 100mA) for one alarm (default), or two groups of relay output (2NO+2NC, 24V 100mA) for high/low alarm (optional).
    Alarms Sound, light
    Display High light nixie tube display
    Installation Wall-mounted, piping type, flow-type (according to the detected environment)
    Connection Power connection type: G1/2 male thread explosion-proof flexible pipe
    Pipe-mounted type: M45*P2.0
    Operating Time 24h
    Explosion-proof Grade Ⅱ 2G Ex ia Ⅱ CT4 Ga
    Protection Grade IP65
    Certification CE, ATEX (Standard: EN IEC 60079-0:2018, EN 60079-1:2014)
    Working Voltage 12-36V DC
    Case Material Die-casting aluminum housing
    Operating Temperature -20℃~50℃
    Operating Humidity 0~95%RH (non-condensing)
    Dimension 206*179*90mm
    Weight ≤1.6kg
    Accessories Power adapter: Input 100-240VAC 50/60Hz, Output 24VDC 1A (Optional USA plug, Europe plug or UK plug)

    Note: To measure confined spaces such as pipelines, please contact us and inform the detailed conditions of use.

    Fixed Carbon Dioxide (CO2) Gas Detector Dimension (Unit: mm)

    Fixed gas detector with alarm dimension

    ***Other Common Gases and Ranges Available for Fixed Gas Detectors

    Gas Type Measure Range Resolution
    Ammonia (NH3) 0-50/100/200/500/1000/2000/5000ppm 0.01ppm/0.1ppm/1ppm
    Benzene (C6H6) 0-1/10/50/100/200/1000/2000/5000/10000ppm 0.001ppm/0.01ppm/0.1ppm/1ppm
    Carbon Dioxide (CO2) 0-1000/2000/5000/9999ppm, 0-2/5/10/20/25/30/50/100%VOL 0.1ppm/1ppm/0.001%VOL/0.01%VOL/0.1%VOL
    Carbon Monoxide (CO) 0-10/20/50/100/500/1000/2000ppm 0.01ppm/0.1ppm/1ppm
    Chlorine (Cl2) 0-5/10/20/50/100ppm 0.001ppm/0.01ppm/0.1ppm
    Chlorine Dioxide (ClO2) 0-1/5/10/20/50/100ppm 0.001ppm/0.01ppm/0.1ppm
    Combustible Gas (EX) 0-100%LEL 1%LEL
    Ethylene (C2H4) 0-10/20/50/100/500/1000/2000ppm 0.01ppm/0.1ppm/1ppm
    Formaldehyde (CH2O) 0-10/20/50/100/500/1000ppm 0.01ppm/0.1ppm/1ppm
    Hydrocarbons (HC) 0-100%LEL 1%LEL
    Hydrogen (H2) 0-10/20/500/1000/2000/5000/9999ppm, 0-2/4% VOL, 0-100% LEL 0.1ppm/1ppm/0.001%VOL/1%LEL
    Hydrogen Chloride (HCL) 0-10/20/50/100/200ppm 0.01ppm/0.1ppm
    Hydrogen Cyanide (HCN) 0-10/20/50/100ppm 0.01ppm/0.1ppm
    Hydrogen Sulfide (H2S) 0-5/20/50/100/200ppm 0.001ppm/0.01ppm/0.1ppm
    Methane (CH4) 0-50/100%VOL, 0-100%LEL 0.01%VOL/0.1%VOL/1%LEL
    Nitric Oxide (NO) 0-1/5/10/20/50/100/250/500/1000ppm 0.001ppm/0.01ppm/0.1ppm/1ppm
    Nitrogen (N2) 0-99.99/0-100%VOL 0.01%VOL/0.1%VOL
    Nitrogen Dioxide (NO2) 0-1/5/10/20/50/100/500/1000ppm 0.001ppm/0.01ppm/0.1ppm/1ppm
    Nitrogen Oxides (NOX) 0-1/5/10/20/50/100/250/500/1000ppm 0.001ppm/0.01ppm/0.1ppm/1ppm
    Oxygen (O2) 0-25/30/100%VOL 0.01%VOL/0.1%VOL
    Ozone (O3) 0-1/5/10/20/50/100ppm 0.001ppm/0.01ppm/0.1ppm
    Phosphine (PH3) 0-10/20/50/100/500/1000/2000/3000ppm 0.01ppm/0.1ppm/1ppm
    Sulfur Dioxide (SO2) 0-1/5/10/20/50/100/500/1000ppm 0.001ppm/0.01ppm/0.1ppm/1ppm
    Volatile Organic Compounds (VOC) 0-1/5/10/20/50/100/200/500/1000/2000/5000/10000ppm 0.001ppm/0.01ppm/0.1ppm/1ppm

    Note: Some common gases and the measuring ranges are listed in the above table. For more information, please feel free to contact us.

    Details

    Fixed Carbon Dioxide (CO2) Gas Detector Details

    Tips: Precautions for carbon dioxide gas detector calibration.

    1. The calibration personnel must be trained, understand the principle and performance of carbon dioxide gas detector, be proficient in operating skills, and hold a certificate.
    2. The adjustment personnel must strictly follow the operating procedures.
    3. CO2 gas detector must be measured and appraised and can be used only after it is qualified.
    4. Before calibrating the carbon dioxide gas detector, perform a visual inspection. Calibration can be started after confirming the appearance is intact.
    5. CO2 gas detector that needs to be calibrated should be warmed up for about 20 minutes. Zero the carbon dioxide gas detector in fresh air.
    6. After the zero adjustment is completed, pass a standard gas sample with a concentration of about 1.0% according to the flow specified in the manual. Calibrate the displayed value of the carbon dioxide gas detector. The indicated value is consistent with the standard gas value and can be used after it is stable.

    Gas Detector 3-Wire System

    In the realm of gas detection systems, the 3-wire configuration offers a robust wiring solution, especially for applications requiring analog output. This video will show you the 3-wire gas detector wiring.

    Gas Detector 4-Wire System

    The wiring of the 4-wire gas detector supports the RS485 interface Modbus RTU communication mode. This video will show you the 4-wire gas detector wiring.

    Using Cloud Data and 4G for Fixed Gas Detectors

    This video will show you about the applications of cloud data and 4G transmission for fixed gas detectors.

    Monitoring Combustible Gas in Pipelines

    This video will show you how to monitoring combustible gas in pipelines.

    Existing reviews of Fixed Carbon Dioxide (CO2) Gas Detector, 0 to 9999 ppm
    Working environment of gas detector
    Hi, I was wondering if the handheld carbon monoxide (CO) gas detector would work in a hydrogen rich environment?
    From: Hart | Date: 27/09/2021
    Was this review helpful? Yes No (0/0)
    ATO Responded
    Generally, H2 and CO gases interfere with each other, and all sensors in the market can not do measurement without some little interference. But our gas detector sensor is of high quality, and the relative interference will be much smaller.
    Questions about gas detection
    I have one more question about the calibration of H2S gas. Do I need to have pure H2S gas or mixture of H2S CH4 also work?
    From: Lxxv | Date: 06/09/2021
    Was this review helpful? Yes No (0/0)
    ATO Responded
    Yes, for the calibration of H2S gas, it can use pure H2S gas (As long as the concentration of H2S does not exceed the gas detector) or mixture of H2S+CH4, both are ok.
    Load more reviews...
    Write your review for Fixed Carbon Dioxide (CO2) Gas Detector, 0 to 9999 ppm
    • Only registered users can write reviews
    • Bad
    • Excellent
    Customers who bought this item also bought

    Fixed Nitrogen (N2) Gas Detector, 0 to 100% Vol

    $742.46
    SKU: GD300-N2
    Buy nitrogen gas detector from high-quality manufacturer at good price. Measuring range 0-100% Vol, supports remote control, optional output signal 4-20mA and RS485, high accuracy 3% F.S, fast response within 10s. N2 gas detector for nitrogen concentration detecting and leak monitor, sound and light alarm, 24h online, real-time display, fixed mounting.

    Fixed Hydrogen (H2) Gas Detector, 0 to 1000/2000/5000 ppm

    $634.77
    SKU: GD300-H2
    Affordable price hydrogen gas detector for sale. Optional measuring range 0-1000/2000/5000 ppm, max 10000 ppm, supports remote control with output signal 4-20mA and RS485, high accuracy 3% F.S. H2 gas leak detector for hydrogen concentration detecting with sound & light alarm, fixed design, compact structure.

    Fixed Combustible Gas Detector, 0 to 100%LEL

    $526.67
    SKU: GD300-EX
    Combustible gas detector is fixed to detect the flammable gas leakage and gives the alarm with sound and light. With real-time display and remote control, flammable gas detector is available with signal output 4-20mA and RS485, fast response and high accuracy.