Digital clamp meter is a smart automatic measuring clamp multimeter by pressing the function key, with AC current range 0-400A, AC/DC voltage range 0-600V, resistance range 0-10MΩ, frequency range 0-1000kHz and maximum jaw opening size 25mm. Digital clamp meter has an NCV (non-contact voltage) measuring key to use NCV function. The NCV buzzer and indicator light will alarm frequently if high voltage is detected.
AC clamp meter is a digital clamp multimeter with a selection dial. Digital clamp meter has the measuring range of AC current 0-400A, AC/DC voltage 0-600V, resistance 0-10MΩ, frequency 0-1000kHz, capacitance 0-100mF and temperature -40℃~+1000℃ (-40℉~1832℉). Digital clamp meter has Ture-RMS and NCV functions. The maximum jaw opening size is 25mm.
The mini digital clamp meter is a AC/DC clamp multimeter with TRMS/NCV/temperature/capacitance functions. It can be used to measuring AC/DC current 0-100A, AC/DC voltage 0-600V, resistance 0-20MΩ, frequency 0-100kHz, capacitance 0-100mF and temperature -50℃~+1000℃ (-58℉~1832℉). The maximum jaw opening size is 22mm.
The mini clamp meter is a basic True-RMS clamp meter with AC current range 0-600A, AC/DC voltage range 0-600V, resistance range 0-2MΩ and maximum jaw opening size 28mm. Digital mini clamp meter also has special functions of diode test, on-off buzzer, data hold, automatic power off, overload protection, manual range selection and white backlight.
The mini clamp meter is a digital clamp multimeter can be used to measuring AC current 0-600A, AC/DC voltage 0-600V, resistance 0-20MΩ, frequency 0-100kHz, capacitance 0-100mF and temperature -40℃~+1000℃ (-40℉~1832℉). Digital mini clamp meter has special functions of NCV and TRMS. The maximum jaw opening size is 28mm.
The mini clamp meter is a digital clamp meter can be used to measuring AC/DC current 0-600A, AC/DC voltage 0-600V, capacitance 0-100mF, temperature -50℃~+1000℃ (-58℉~1832℉), resistance 0-60MΩ and frequency 0-10MHz. The maximum jaw opening size is 28mm. Digital AC/DC clamp meter has special functions of True RMS, diode test, backlight and inspection light.
AC clamp meter has AC current range 0-600A, AC/DC voltage range 0-600V, resistance range 0-20MΩ, maximum display value 1999 and maximum jaw opening size 36mm. True RMS clamp meter can be used for sine wave signal measurement. AC clamp meter also has special functions of automatic power off, back light and LED torch.
Clamp meter with TRMS/NCV/LED torch functions has the measuring range of AC current 0-600A, AC/DC voltage 0-600V, resistance 0-20MΩ, frequency 0-100kHz, capacitance 0-100mF, temperature -40℃~+1000℃ (-40℉~1832℉) and duty ratio 0.1%~99.9%. The maximum jaw opening size is 36mm.
The AC/DC clamp meter is a digital clamp multimeter can be used to measuring AC/DC current 0-600A, AC/DC voltage 0-600V, resistance 0-20MΩ, capacitance 0-100mF, temperature -50℃~+1000℃ (-58℉~1832℉) and frequency 0-100kHz. The maximum jaw opening size is 36mm. Digital AC/DC clamp meter has special functions of True RMS, peak hold, overload protection and LED torch.
Digital clamp meter with temperature function has the measuring range of -50℃~+1000℃ (-58℉~1832℉), duty ratio 10%~90%, AC current 0-600A, AC/DC voltage 0-600V, resistance 0-60MΩ, frequency 0-10MHz and capacitance 0-100mF. The maximum jaw opening size is 36mm. Digital clamp meter also has special functin of non-contact voltage test and True RMS measurement for sine wave signal.
The digital clamp meter is an AC clamp meter with AC current range 0-1000A, AC voltage range 0-750V, DC voltage range 0-1000V, resistance range 0-2000MΩ and maximum jaw opening size 55mm. AC clamp meter also has special functions of white backlight, automatic power off, manual range selection, data hold, diode test, on-off buzzer and overload protection.
The current clamp meter is a special mini clamp meter for AC/DC current measurement. The AC/DC current measuring range is 0-80A and NCV measuring range is AC 100~600V. Mini current clamp meter has high resolution 1mA and sampling rate 2.5 times/s. The maximum jaw opening size is 18mm.
AC/DC current clamp meter is a digital clamp multimeter with measuring range of AC/DC current 0-200A, AC/DC 0-600V, resistance 0-999.9Ω and NCV AC 100~600V. The maximum jaw opening size is 18mm. Current clamp meter also has special functions such as NCV, analog display, diode test, on-off buzzer, peak value hold, LED torch, zero resetting, etc.
The digital current clamp meter is a special mini clamp meter for circuit leakage current and AC leakage current test. The leakage current measuring range is AC 0-200mA/0-2A/0-200A and the corresponding resolution is 0.1mA/1mA/100mA. Mini leakage current clamp meter also has special functions such as data hold, automatic power off, overload protection and backlight. The maximum jaw opening size is 1.2" (30mm).
As one of the necessary test tools for electricians' daily maintenance work, the clamp meter is mainly used for the occasion of measuring the current without disconnecting the circuit. The clamp meter is used to measure the related parameters of circular such as current, voltage and resistance. Some models can also measure frequency, capacitor and temperature. The measured data is displayed directly on the LCD display of clamp meter and the data can be held for easy reading and recording. The new smart clamp meter also features automatic range, TRMS and NCV functions. According to the current measurement principle, the clamp meter can be divided into AC clamp meter (only AC current can be measured) and AC/DC clamp meter (both AC current and DC current can be measured through function selection). ATO clamp meters are CE/FCC/ROHS certified. The more you buy at one time, the cheaper the price of the digital clamp meters.