Close
(0) Shopping cart
You have no items in your shopping cart.
Shopping Categories
    Filters
    Preferences
    Search

    5 hp VFD, Single Phase to Three Phase VFD

    4.9 out of 5 based on 32 reviews | Write a review
    $294.31
    5hp variable frequency drive, single phase to three phase VFD, 17 amps, RS485 enabled, shipping weight 4kg, manufacturer direct sale.
    SKU: GK3000-2S0037
    Availability: In stock
    30-day Returns
    Free Shipping
    Delivery date: 2-3 days

    Single phase 5 hp VFD, single phase 220V to three phase variable frequency drive, 17 amps. Using it as a phase converter to convert 1-phase 220v (230v, 240v) home power supply to drive 3-phase motors.

    Specification:

    Basics Model GK3000-2S0037
    Capacity 5 hp (3.7 kW)
    Shipping weight 4 kg
    Dimension 230*118*163 mm
    I/O Feature Rated current 17 A
    Input voltage 1 phase 220~240V AC
    Input frequency 50Hz/ 60Hz
    Output voltage 3 phase AC 0~input voltage
    Output frequency 0Hz~1000Hz
    Over load capacity 150% of rated current for 1 minute, 180% of rated current for 3 seconds
    Control Feature Control mode V/F, Sensorless vector control (SVC), Speed sensor vector control (FVC)
    Communication RS485
    Speed regulation 1:100
    Start torque 150% of rating torque at 1 Hz
    Speed control accuracy ≤±0.5% of rating synchronous speed
    Frequency precision Digital setting: max frequency x± 0.01%;
    Analog setting: max frequency x± 0.2%
    Frequency resolution Analog setting: 0.1% of max frequency;
    Digital setting: 0.01Hz
    Torque boost Automatic torque boost, manual torque boost 0.1%~30.0%
    Interior PID controller Be convenient to make closed-loop system
    Automatic energy save running Optimize V/F curve automatically based on the load to realize power save running
    Automatic voltage regulation (AVR) Can keep constant output voltage when power source voltage varies.
    Automatic current limiting Limit running current automatically to avoid frequent over-current which will cause trip
    Environment Enclosure rating IP 20
    Temperature –10℃~ +40℃; VFD will be derated if ambient temperature exceed 40℃; each rise 1℃, the derate will be 5%
    Humidity 5%-95%, without condensation
    Altitude ≤1000m; VFD will be derated if above 1000m
    Impingement and oscillation Normal running:<5.9m/s2 (0.6g); Transportation:<15m/s2 (1.5g)
    Store environment –20℃~ +60℃; no dust, no corrosive gas, no direct sunlight

    Note: ATO VFD Cannot be used as a power source, it Can only be directly connected to an induction motor to control the motor speed.

    Details

    5 hp Single Phase to Three Phase VFD Details

    Tips: Variable frequency drive application in rotary sushi and rotary hotpot
    Rotary Sushi is a kind of food that can be directly taken from the seat, which is more convenient than ordinary buffet. Diners can continue to get direct stimuli and continue to consume. The food display is on-site, and is tightly bound to the consumption process, and the consumer purchase decision-making cost is the lowest. In the whole process of eating, rotary food conveyor belt is an important part to ensure food lively and continuous offering. If there is large sum of customers, the food transporting speed should be slightly faster; in the opposite, it can be slightly slower. VFD has wide speed regulation range, high precision, starts smooth, small size, low noise, long life and other characteristics, and has been widely used in rotary sushi conveyor belt, rotary hotpot conveyor belt and other transport equipments in catering industry.
    VFD transformation effect:

    1. Smoothly start and stop, preventing food falling.
    2. Can achieve stepless speed adjusting, wide range of speed, according to the number of customer to adjust transporting speed.
    3. Better protection to motor.
    4. Save energy, the rate of power saving can be more than 50%.
    5. Can positive and negative rotate, and easy to switch.
    Existing reviews of 5 hp VFD, Single Phase to Three Phase VFD
    Using 3 wire control
    I have vfd GK3000-2S0037 on my bridgeport milling machine and I was wanting to use 3 wire control to use the original forward/off/reverse switch. Could you tell me which location the wires need to go to and also the parameters I need to set to do this.
    From: Theresa | Date: 29/10/2024
    Was this review helpful? Yes No (0/0)
    ATO Responded
    For three-wire control, please refer to our setup manual P3 and video.
    Manual: https://www.ato.com/Content/doc/VFD-quick-setup-manual-and-application.pdf
    Video: https://www.youtube.com/watch?v=KERNV5omUNs&list=PLlo8RulDRnthB_yJeKHLcVVbUFz2r9ked&index=11
    If you still encounter problems, you can provide us with your on-site wiring diagram and the parameters you set.
    The motor speed
    I got the table saw up and running this past weekend and I am pleased with the VFD. I purchased Model GK3000-2S0037G to run a table saw with a 5HP 9-lead 3-phase motor which can run on either 230V or 460V. It is set up to run on the lower voltage obviously.  
    I have one other question: In general, the saw cuts through normal wood like butter; however, when I went to cut a thicker piece of cherry, the motor slowed a bit. The blade is sharp and the motor is a 5 HP so I don't believe the motor should have slowed much at all. The VFD is connected to a 30 AMP 240 circuit so that shouldn't be the problem. Is there a setting I should change which would help?
    From: Rache | Date: 11/10/2024
    Was this review helpful? Yes No (0/0)
    ATO Responded
    Regarding the "when I went to cut a thicker piece of cherry, the motor slowed a bit", did the VFD give out a fault code in this case?
    If the VFD gives out an alarm, it means that the motor capacity is small; if the VFD fails, it means that when processing thick wood, the load increases and the current is high. We recommend that when processing thick wood, your cutting speed should be reduced due to the increased load.
    You can click the shift key>> when the VFD is running with a thicker piece of cherry, shift to b0.04, and check the current (A) displayed by the VFD in real time.
    I have some questions
    How long is your standard shipping? I watched the video you sent, very nice! I'm still very unsure about P6.30-Given pressure. I would really like to understand if/how this value is used, and I do not believe it is the 'target pressure' as you stated. You use the term 'set pressure' in your description, which Px.xx number is that referring to? What makes me think P6.30 is not used is the fact that it is set to a number MUCH higher than the wake-up and sleep pressures. Finally, I'm wondering about safety. What happens if my pressure sensor fails. Is there anything that will stop the pump running forever/until it overheats. Is it possible to add maybe a temperature sensor based shut-off, or a backup pressure sensor?
    From: Gabrie | Date: 22/09/2024
    Was this review helpful? Yes No (0/0)
    ATO Responded
    1. This unit 5hp drive, model: GK3000-2S0037 is in stock at our US warehouse, and we can ship directly from the US, which can shorten the delivery time. Just place an order and tell us to ship from the US warehouse.
    2. The set pressure of P6.30 is also equivalent to the target pressure. Its relationship with the sleep pressure can be set in the parameter P6.41, the actual pressure or 100% pressure.
    Because the pressure in the bucket is limited in our demonstration video, the values are very small when setting these pressure values. As long as the pressure rises to the sleep pressure level, the VFD will go to sleep. The whole operation is just based on demonstration, and the actual pressure value needs to be set according to the user's water pressure system.
    3. Regarding safety issues, in the constant pressure water supply setting, if the pressure sensor is damaged, we have feedback signal disconnection detection P6.26/P6.27, and the system is protected.
    After you purchase this VFD, you can carefully check the introduction of the VFD about the P6 parameter group.
    5hp single phase to 3 phase VFD on/off switch
    I have the 5 hp single phase to 3 phase VFD controlling a 3 phase motor on a vacuum pump.
    I need to be able to use an on/off  (non-resetting) switch to power on unit.
    All the videos you provide and the quick setup guides use a momentary self resetting push button.
    From: Brandon | Date: 13/04/2024
    Was this review helpful? Yes No (0/0)
    ATO Responded
    You can use the 2-wire control mode without forward rotation or reverse rotation to achieve your needs.
    I just purchased VFD
    Hi, I just purchased VFD and I cannot get it to let me adjust the output hertz greater than 50 hertz.  I've looked at the manual and videos, and it allows me to set it to anything below 50, but not above 50. I need to set it to 60hertz. Thank you for your help.
    From: Blake | Date: 05/02/2024
    Was this review helpful? Yes No (0/0)
    ATO Responded
    You can refer to the attached quick setting document instructions. You need to set P0.05=P0.06=60 (maximum output frequency) and P8.04=60 (motor rated frequency)
    Please advise
    I purchased a single phase to three phase vfd in October. It has been wired according to manual, but does not power on. Please advise
    From: Derby | Date: 08/01/2024
    Was this review helpful? Yes No (0/0)
    ATO Responded
    The input single-phase 220V voltage of the VFD you purchased is connected to the R/S terminal (the T terminal is not connected if the screw is removed), and the output terminals U, V, and W are connected to the three-phase motor.

    You can try running the VFD without load and check if it can run normally to 50/60HZ. If there is No problem with the above operations, you can try connecting the motor again.
    Single Phase to Three Phase VFD
    The ground wire from 220 power supply. Why does terminal T have no screw, motor side ground, PE, and no PE terminal?
    From: Benjamin | Date: 07/01/2024
    Was this review helpful? Yes No (0/0)
    ATO Responded
    Terminal T. No screw, this terminal is Not used. You can connect single-phase 220V to the R, S terminals, and the U, V, W terminals to the three-phase motor. The terminal marked E is connected to the ground.
    set the frequency
    It still will not allow me to set the frequency higher than 320
    From: Oliver | Date: 06/11/2023
    Was this review helpful? Yes No (0/0)
    ATO Responded
    After you set P0.21=1, P0.05 and P0.06 will become 500HZ, and then you need to modify P8.04 (motor output frequency). Please provide a video showing us how you set these parameters. So we can proceed to the next step. You can send us the large video file via wetransfer.com.
    Gas Generator
    Can I use this VFD to run a 3 hp, 3 phase 230V submerged motor/pump with the input of a 1 phase 240V gas generator?
    From: Eric | Date: 13/10/2023
    Was this review helpful? Yes No (0/0)
    ATO Responded
    No, the VFD can only be used as a driver for a motor. the output circuit of the VFD cannot contain any circuits other than the motor.
    Max frequency issue
    i purchased this vfd and it will not allow me to set the max Hz over 320hz i can't figure it out.
    From: michael | Date: 23/09/2023
    Was this review helpful? Yes No (0/0)
    ATO Responded
    Please take a photo of the nameplate of your 5 hp, single-phase to three-phase VFD, send it to our support@ato.com email address, and describe your problem, and our after-sales team will contact you.
    Some questions on wiring and parameters
    I have some questions on wiring and parameters. I want to press a momentary start button (forward only) to run vfd. I want to press a momentary stop button to stop / reset vfd. How do I configure the vfd for this mode? I also want to send positive logic ( 24vdc) to the X1-X6 inputs. How do I configure the jumpers to allow for that type of logic? Can I use  24v terminal as the source for the start / stop buttons? I would appreciate the help and fast response.
    From: nancy | Date: 04/09/2023
    Was this review helpful? Yes No (0/0)
    ATO Responded
    1. If you only need to start (only forward) and stop running the motor, please refer to our quick set document settings. Wiring: input to L, N terminals, output to U, V, W terminals.
    2. About send positive logic (+24vdc) to the X1-X6 inputs. Please remove the original 24V and OP short wire, and follow the connection method in the attachment.
    3. NPN and PNP conversion setting parameter P3.41, please refer to the manual P132.
    How do I enable VFD parameters PO.19, PO.07 to be changed?
    I just received the 5hp single phase to 3 phase VFD and want to change running frequency from default 50Hz to 60Hz.
    PO.02 states that it is a modifiable parameter, contingent on PO.19 being set to allow this. This parameter is unmodifiable because it is in the running state.
    My question is: How do I enable parameters PO.19, PO.07, etc to be changed?
    From: cathy | Date: 13/06/2023
    Was this review helpful? Yes No (0/0)
    ATO Responded
    1. Please provide us with the order number to further confirm what product you purchased. We hope to provide you with better service.
    2. Please set the output frequency of the VFD to 60Hz.
    You can also refer to our demo video: https://www.youtube.com/watch?v=s6tTQdAVliM&list=PLlo8RulDRnthBFbP4ydheukDSKw2hAfDn&index=17
    Is it possible to exchange the 5 HP vfd?
    Hello, Attached is the receipt for my order, and attached is also images of the device I received. It is not the correct device and require 3 phase power which I do not have access to. Is it possible to exchange the product?
    From: coty | Date: 10/05/2023
    Was this review helpful? Yes No (0/0)
    ATO Responded
    Sorry to bother you, but we believe this is the correct product model. Perhaps we can help to solve the your problems.
    If you look closely, you can see that the T-terminal screw on the input terminal has been removed, since this terminal is not used.
    You just need to connect the single-phase AC 220v power supply to the R-S terminal, and then please connect the three-phase motor to the U-V-W terminal.
    Please refer to our demo video:
    https://www.youtube.com/watch?v=s6tTQdAVliM&list=PLlo8RulDRnthBFbP4ydheukDSKw2hAfDn&index=17
    https://www.youtube.com/watch?v=nBUm4i9wnzY&list=PLlo8RulDRnthBFbP4ydheukDSKw2hAfDn&index=12
    Please try again and thanks for your understanding.
    No current coming from the VFD sensor
    Well, you can ignore the previous email. I went and purchased a better multi meter. I have no current coming from the sensor at any speed of the pump motor.
    With negative from sensor to positive of meter and negative of meter to gnd on VFD all measure zero on DC mA on the meter.
    I think it would be best just to exchange the transducer at this point. Can you pretest it before sending it out? I have wasted a lot of time on this install.
    From: lekah | Date: 07/04/2023
    Was this review helpful? Yes No (0/0)
    ATO Responded
    We are really sorry for bringing you such a bad experience. We think your sensor part may lack settings, and you need to convert 1.6Mpa to 232psi, and set 232 into IUH. Please refer to the attached file for settings. Please check the output again.
    Does different versions of this sensor of VFD have different guides?
    Thank you for the reply. The sensor transmitter I have does not have those settings in the advanced menu with pin 00016. What I see are in the attached files.
    Also the online manual and the manual you attached last night via email appear to be different versions. Neither match my sensor. Just how many versions of this sensor have different guides?
    From: reggie | Date: 06/04/2023
    Was this review helpful? Yes No (0/0)
    ATO Responded
    Thanks for the detailed photos for your feedback. This pressure sensor is another version, it is a little bit different from the manual we sent yesterday.
    According to the photos you provided, we confirm that your pressure sensor parameter settings are correct, and you have set the pressure range 232PSI. Now, you can run the VFD and the pump. When the VFD's operating frequency reaches 60Hz, please check the PSI pressure value displayed on the pressure sensor panel.
    In addition, please use a multi meter to measure whether the current signal output by the pressure sensor. We want to know whether the pressure displayed by the pressure sensor is consistent with the output signal when the motor is running at 60Hz.
    Input voltage abnormally
    I purchased a vfd and I am using it to convert power for my drill press. It works good except that when I use the drill press switch to turn off the drill and then the switch to turn it back on the vfd come up with error code E-07 or E-06. The user manual suggest that it is abnormal input voltage. I have checked it with a multi-meter and it stays between 220-250v. I have the vfd plugged into the wall and have used the outlet to run other tools (off the single phase 220 outlet) and they run no problem. Just wondering if you have any solutions.
    From: Keran | Date: 04/04/2023
    Was this review helpful? Yes No (0/0)
    ATO Responded
    You mentioned that the VFD input voltage stays between 220-250V, but what is the voltage most of the time? Due to the relatively large fluctuations in the input voltage, the VFD should have overvoltage protection. You can try to set the VFD overvoltage protection point parameter P9.11=800, and test again. If possible, please try to control the VFD input voltage at around 230V. Also note: VFDs can only be used to connect motors, but are not suitable for powering machine tools.
    Can it be used with circular knitting machine?
    we have source of 1 PHASE 240VAC 60 Hz and want to power up a fully automatic circular knitting machine 3 PHASE 240VAC 60Hz (3kW). Can this device perform this task with long term reliability. or can you recommend something else. thank you.
    From: ROBIN | Date: 04/03/2023
    Was this review helpful? Yes No (0/0)
    ATO Responded
    Yes, your doubt will be solved via this 5 hp VFD. ATO VFD always supply high quality and stable working ability. Its working condition is matching your system request, including, powering up, power capacity, long term operation reliability and so on.
    Questions about 5HP VFD
    Is the internal fan on the 5HP VFD supposed to run all the time the pump motor is running?
    From: Aldrich | Date: 03/03/2023
    Was this review helpful? Yes No (0/0)
    ATO Responded
    As long as the 5HP VFD is running, the fan will automatically run; when the VFD is stopped, the fan will also stop. So if the VFD is running, but the fan is not, then there is something wrong with the fan.
    I want to set up a 5HP VFD to run a vehicle lift
    I would like to set up your single phase to three phase 5HP VFD to run a vehicle lift. I would like to use the existing safety switch and motor control. I have two questions.

    1. Do the rev and fwd terminals need continuous closed circuit voltage to operate or does it momentarily cause it to run indefinitely?
    2. Can I use the P24 terminal to operate the rev and fwd functions through the existing motor controls?
    From: RIvan | Date: 12/12/2022
    Was this review helpful? Yes No (0/0)
    ATO Responded
    Our single-phase to three-phase 5HP VFDs do not support direct connection to external control voltages, but only to COM via the internal control signal terminals.
    Application for 5kW Aircon
    Here's my problem; I bought an 5 kW 220V aircon which is 3 phase but the power provision is single phase; Can I use VFD for converting single phase into 3 phase? Any recommendation or suggestion is highly appreciated. thanks
    From: Marc | Date: 21/08/2022
    Was this review helpful? Yes No (0/0)
    ATO Responded
    ATO 5 hp (3.7kW) VFD couldn't satisfy system as your request. There are two solutions as follows:
    1. You can continuously use this 5 hp VFD, but you should use it to control compressor or fan only which power capacity is lower than 3.7kW.
    2. We highly recommend you select our 7.5 hp VFD (SKU: GK3000-2S0037), which may meet your needs.
    Any suggestions for what I should look at?
    I have a GK3000-2S0037G that I am using with a 3.5kw spindle. When I enable the spindle, I get an E-01 error message and my P6.05 value is 303V. My spindle is rated at 220v/380v and my P0.08 value is 220. Any suggestions for what I should look at?
    From: Bourdon | Date: 27/07/2022
    Was this review helpful? Yes No (0/0)
    ATO Responded
    In order to better solve your problem,
    1. Please provide us with the motor nameplate for confirmation.
    2. Please let us know if your current wiring is 220V or 380V?
    Can you provide a program sheet to configure the VFD to this spindle?
    I have purchased GK3000-2S0037G Power 3.7KW Input AC 1PH 220V 50/60HZ Output AC 3PH 0-220v 0-500HZ 19.2A. And I am trying to configure it for a Giordano Colombo Spindle 380V 400Hz 24000 RPM 3HP 2 pole spindle. Can you provide a program sheet to configure the VFD to this spindle? I have tried and burnt up one spindle already.
    From: Martin | Date: 26/05/2022
    Was this review helpful? Yes No (0/0)
    ATO Responded
    No, the output voltage of the GK3000-2S0037G you purchased can only be three-phase 220V, it cannot be used for three-phase 380V spindle motor, which will burn your motor.
    If your spindle motor is three-phase 380V, and the input power voltage is single-phase 220V, it is recommended that you use our 1-Phase 220V to 3-Phase 380V VFD, see spec and price on: https://www.ato.com/10-hp-vfd-1-phase-220v-to-3-phase-380v
    I want to ask a question about the 5 hp VFD
    Can a braking resistor be installed on your 5hp single to 3 phase VFD?
    From: Jame | Date: 15/11/2021
    Was this review helpful? Yes No (0/0)
    ATO Responded
    Yes, you can do so. Also, you can use it without resistor.
    5 hp VFD operation
    Recently, we bought one unit of inverter GK3000-2S0037G.
    We found the LED display "50.00" flashing after displaying "y-H" when power up on the terminal R, S with single phase 230VAC. Then any button can not be operated.
    From: Gmead | Date: 13/09/2021
    Was this review helpful? Yes No (0/0)
    ATO Responded
    We are sorry for that. When the power is on, the VFD display "Y-H" is normal. The problem is that the operation button cannot be operated.
    So, has your VFD keyboard been changed? Could you provide a video to show the problem that the keyboard button cannot be operated for our reference and confirmation?
    High quality 5 hp VFD
    I just purchased your GK3000-2S0037G VFD for my 3 phase planer that I am going to run of of 220V AC.
    I am hoping to add an on/off toggle switch and was wondering if I run the wires for it to the COM and OC1 terminal.
    Also, do I need to program that switch or will it just recognize it and it will function as an on/off.
    Thanks you for the help, Luke.
    From: Nchiker | Date: 12/09/2021
    Was this review helpful? Yes No (0/0)
    ATO Responded
    Yes, our VFD can add external toggle switch to realize start/stop operation, the specific steps are as follows:
    1.VFD wiring:
    Start switch: the start switch (Normally open contact NO) is connected to terminal FWD and terminal COM
    Stop switch: The stop switch (Normally open contact NO) connect the stop switch to terminal COM and terminal X1.
    2.Set as following:
    P0.03=1 (run command from terminal)
    P4.08=0 (2-wire control mode 1)
    P4.00=13 (Define terminal X1 as stop signal)
    When you press Emergency stop, X1 and COM will be connected, and VFD will stop.
    And you can also refer to the video for VFD terminal control:https://www.youtube.com/watch?v=nBUm4i9wnzY&list=PLlo8RulDRnthBFbP4ydheukDSKw2hAfDn&index=12
    I recently purchased a VFD from you guys
    I recently purchased a VFD from you guys.
    VFD related information
    Model #GK3000-2S0037G.
    Power: 3.7kW
    Input: 220VAC 1Ph 50-60Hz
    Output: 0-220VAC 3 Ph 0-500Hz
    I want to size a braking resistor for this VFD, but could not find the information table in the manual. Can you provide the recommended resistance and resistance power for this specific VFD?
    From: Rachelle | Date: 01/09/2021
    Was this review helpful? Yes No (0/0)
    ATO Responded
    Recommended braking resistance: 75Ω 800W.
    5 hp VFD installation
    Can a braking resistor be installed on your 5 hp single phase to three phase VFD?
    From: Candid | Date: 15/07/2021
    Was this review helpful? Yes No (0/0)
    ATO Responded
    Yes, you can do so. Also, you can use it without resistor.
    Ran well for a year, purchasing another
    I bought this VFD last year to set up a back-yard ski lift. (700ft surface rope-tow powered by 5hp 3phase motor, run off single phase 220V house current.)  The manual to figure out the programming definitely took some effort to understand but eventually I was able to set up the system with remote safety shut-off and speed control as well as remote indicator lights. I ran the system all winter without any problems (had error code shut-offs a few times but they were due to mechanical load issues.)
    This year we are building a second lift with a similar design and since this VFD worked well for me all last year (and I've already done the hard work of figuring out how to program and wire it), I will be buying a duplicate VFD for the new lift.
    I'm not one to write reviews but I figure that if it worked well enough for a year that I'm buying a second one, it's worth posting a positive review.
    From: David | Date: 20/11/2020
    Was this review helpful? Yes No (1/0)
    Excellent value
    Excellent value for the money.for home use it seems to work well.
    From: wu | Date: 19/10/2018
    Was this review helpful? Yes No (0/0)
    Works great
    I have this drive (5HP capacity 1ph To 3ph VFD) installed and have tested it. It works great. I programmed it last night for the 3 wire start/stop control. I am pleased with this VFD and may eventually buy another one as well. Thanks
    From: Rudo | Date: 04/05/2018
    Was this review helpful? Yes No (3/0)
    India distributor
    Do you have any distributor/importer in India? Interested to import/market in INDIA, particularly 220 single phase input and 220volts three phase output VFD?
    From: Matthew | Date: 27/04/2018
    Was this review helpful? Yes No (0/0)
    ATO Responded
    Don't have a distributor in India, but we ship our single phase to three phase VFDs world wide (by Air) free of charge and with 18 month warranty.
    Single Phase to Three Phase made EASY
    This is very simple to install and operate, high quality product. Thank you for your quick shipment!
    From: Arlin | Date: 13/10/2017
    Was this review helpful? Yes No (1/0)
    Load more reviews...
    Write your review for 5 hp VFD, Single Phase to Three Phase VFD
    • Only registered users can write reviews
    • Bad
    • Excellent
    Customers who bought this item also bought

    2 hp VFD, Single Phase to Three Phase VFD

    $183.16
    SKU: GK3000-2S0015
    2 hp VFD, convert single phase to three phase for AC motor speed controls, 7 amps, IP20, RS485 enabled, manufacturer direct sale.

    3 hp VFD, Single Phase to Three Phase VFD

    $238.14
    SKU: GK3000-2S0022
    Low price 3hp VFD, convert 220V/230V/240V 1 phase to 3 phase, 9.6 amps, RS485 enabled, shipping weight 3kg, manufacturer direct sale.

    1 hp VFD, Single Phase to Three Phase VFD

    $159.32
    SKU: GK3000-2S0007
    1 hp VFD, convert single phase to three phase for AC motor speed controls, IP20, RS485 enabled, shipping weight 2kg, manufacturer direct sale.

    5 hp VFD, 1-Phase 220V to 3-Phase 380V VFD

    $473.54
    SKU: GK3000-CS0037
    Best 5 hp variable frequency drive at low price. Single phase 220 volt input to three phase 380 volt output VFD for AC motor speed control, IP20, RS485 enabled, V/F and sensorless vector control mode.

    7.5 hp VFD, Single Phase to Three Phase VFD

    $697.14
    SKU: GK3000-2S0055G
    7.5 hp variable frequency drive, single phase to three phase VFD, 28 amps, RS485 enabled, manufacturer direct sale.