High quality laboratory ultra-pure water system for biochemical analyzer matched used, adopt PP, AC filter, RO membrane, purification column, final filter and other technologies.
Specification
Model |
Mobiochem910s/ 920s/ 930s |
Mobiochem910d/ 920d/ 930d |
Process |
Single pass RO system |
Double pass RO system |
Water production capacity |
≥10L/H |
≥10L/H |
Water output rate |
1-1.5L/min |
1-1.5L/min |
Resistivity at 25℃ |
≥5MΩ.cm |
≥5MΩ.cm |
Absorbance (254nm,1cm optical distance) |
≤ 0.01 |
≤ 0.01 |
Reactive Silica (SiO2) |
≤ 0.02ppm |
≤ 0.02ppm |
Heavy metal |
< 0.01ppm |
< 0.01ppm |
Electrical requirements |
220V (230V, 240V) 50Hz |
Power |
≥100W |
≥150W |
Dimension (L/W/H) |
490*550*850mm |
490*550*850mm |
Weight |
≥50KG |
≥55KG |
Tank capacity |
30L |
Note: The model end with 's' has single stage RO module, suitable for feed water inlet TDS<200PPM. Model end with 'd' have double stage RO module, suitable for feed water inlet 200ppm<TDS<400ppm. If feed water inlet TDS>400PPM, suggest an additional industrial type softener.
Product Features
Power on self test, water shortage protection alarm, power-off protection.
Built-in RO membrane fouling prevention program, auto flushing when open and manual RO membrane cleaning button.
Built-in automatic cycle timing of ultra pure water, ultra pure water conservation.
Water resistance/conductivity on-line monitoring, display the running state and parameters.
Pure water tank with cone type structure, a discharge valve at the bottom, easy to clean and disinfect exhausted. Water level auto detection.
Lab Test and Corresponding Water Type List
Test Name |
Type III Water |
Type II Water |
Type I Water |
Lab glassware washing |
√ |
|
|
Hydroponics |
√ |
|
|
Sterilizer use water |
√ |
|
|
Gas generator use water |
√ |
√ |
|
Conventional test |
√ |
|
|
Reagents/ drugs preparation, dilution |
√ |
|
|
Feed water for ultrapure water |
√ |
|
|
IC |
|
√ |
|
LC/LC-MS |
|
|
√ |
HPLC |
|
|
√ |
AAS |
|
|
√ |
ICP/ICP-MS |
|
|
√ |
GC/GC-MS |
|
|
√ |
Trace analysis |
|
|
√ |
TOC analysis |
|
|
√ |
Organic analysis |
|
|
√ |
Inorganic analysis |
|
|
√ |
Environmental analytical test |
|
|
√ |
Microelectronics parts cleaning |
|
|
√ |
Precision instrument use water |
|
|
√ |
Analytical reagent/ drugs preparation, dilution |
|
|
√ |
Mass spectrometry |
|
|
√ |
PCR application/analysis |
|
|
√ |
DNA/RNA research |
|
|
√ |
Proteomics research |
|
|
√ |
Plant and animal cell culture |
|
|
√ |
Toxicity analysis |
|
|
√ |
Microbiology experiment |
|
|
√ |
Immunological experiment |
|
|
√ |
Biochemistry experiment |
|
√ |
|
Serum test |
|
√ |
|
IVF |
|
|
√ |
Main Consumable List (A water purification system is equipped with a set of consumables. If you want to buy some of the following consumables, contact us now.)
No. |
Name |
Specification |
Lifespan |
1 |
PP filter |
1st stage, 10”/20” (5μm) |
3-6 months |
2 |
Activated Carbon filter |
2nd stage, 10”/20” |
6-12 months |
3 |
Softener filter |
3rd stage, 10”/20” |
6-12 months |
4 |
Precision filter |
4th stage, 10”/20” (1μm) |
10-12 months |
5 |
RO membrane |
75g/300g |
1-2 years |
6 |
Ultra purification resin column |
|
1 year |
7 |
Pure water tank |
30L, 80L, 120L |
|
Tips: Laboratory purification water system freezes easily in winter.
If the laboratory purification water system is installed outdoors, the necessary anti-freezing measures must be taken, otherwise this will cause damage to parts. Stop using the laboratory ultrapure water system as soon as the temperature is below 0 ° C.
If it is installed indoors, the temperature must be higher than 0 ℃. If the temperature is too low, the pipes will be cracked and leak.
If you do not use for a long time or need to go out, you must close the water inlet valve to drain all the water from the device.
If you encounter icing, you need to place the entire device in a room with a temperature higher than 10 ° C for 48 hours before you can continue to use it. During this thawing period, do not open the machine.