ATO fixed VOC gas detectors are designed for continuous monitoring, offering reliable performance and durability in harsh industrial conditions. They are typically installed at reliable locations to monitor and detect VOC leaks or emissions.
Features
- VOC gas detector adopts high precision sensor for accurate gas leak detection.
- Volatile Organic Compounds gas detector is equipped with 3-wire system 4-20mA analog output, relay output, RS485 output (optional).
- The VOC gas monitor is compatible with various controlled alarms, PLC, DCS and other control system, and can be remote monitored.
- Explosion-proof design, fast, relaible and stable.
- Infrared ray controller can remote control the alarm point settings, zero calibration, and address modification.
- Two-stage alarm with sound and light, and the alarm point is settable.
- The VOC gas detector has self-calibration function, and three standard keys will be used to realize on-site maintenance.
- Volatile Organic Compounds gas detector can output one or two on-off signals, can drive ventilator, solenoid valve or other external devices.
Specification
Model |
GD300-VOC |
Detection Principle |
PID |
Gas |
Volatile Organic Compounds (VOC) |
Range |
0 to 1 ppm, 0 to 5 ppm, 0 to 10 ppm, 0 to 20 ppm, 0 to 50 ppm, 0 to 100 ppm, 0 to 200 ppm, 0 to 500 ppm, 0 to 1000 ppm, 0 to 2000 ppm, 0 to 5000 ppm, 0 to 10000 ppm |
Resolution |
0.001 ppm (0-1 ppm, 0-5 ppm), 0.01 ppm (0-10 ppm, 0-20 ppm, 0-50 ppm), 0.1 ppm (0-100 ppm, 0-200 ppm), 1 ppm (0-500 ppm, 0-1000 ppm, 0-2000 ppm, 0-5000 ppm, 0-10000 ppm) |
Accuracy |
≤±3% F.S. |
Responce Time |
≤10s |
Repeatability |
≤±1% |
Recovery Time |
≤10s |
Linearity Error |
≤±1% |
Zero Shift |
≤±1% (F.S./year) |
Signal Output (Optional) Note |
4-20mA and RS485 Relay output: one group of relay output (1NO+1NC, 24V 100mA) for one alarm (default), or two groups of relay output (2NO+2NC, 24V 100mA) for high/low alarm (optional). |
Alarms |
Sound, light |
Display |
High light nixie tube display |
Installation |
Wall-mounted, piping type, flow-type (according to the detected environment) |
Connection |
G1/2 is the inlet and outlet for power and signal lines Pipe-mounted type: The installation thread size of the instrument is M45*P2.0 |
Operating Time |
24h |
Explosion-proof Grade |
Ex d llC T6 |
Protection Grade |
IP65 |
Certification |
CE, ATEX |
Working Voltage |
12~36V DC |
Case Material |
Die-casting aluminum housing |
Operating Temperature |
-20℃~50℃ |
Operating Humidity |
0~95%RH (non-condensing) |
Dimension |
206*179*90mm |
Weight |
≤1.6kg |
Accessories |
Power adapter: Input 100-240VAC 50/60Hz, Output 24VDC 1A (Optional USA plug, Europe plug or UK plug) |
Note: To measure confined spaces such as pipelines, please contact us and inform the detailed conditions of use.
Fixed Volatile Organic Compounds (VOC) Gas Detector Dimension (Unit: mm)
***Other Common Gases and Ranges Available for Fixed Gas Detectors
Note: Some common gases and the measuring ranges are listed in the above table. For more information, please feel free to contact us.
Details
Tips: What are VOC gases?
Volatile Organic Compounds (VOCs) are gases released from various solids or liquids and are commonly found in household products, building materials, and industrial processes. These compounds evaporate easily at room temperature, releasing the molecules into the air. Common sources of VOCs include paints, solvents, cleaners, and fuels. While many VOCs are harmless, some may pose health risks, causing indoor and outdoor air pollution. Short-term exposure to high concentrations of VOCs may irritate the eyes, nose, and throat, as well as headaches and nausea. Long-term exposure to certain volatile organic compounds can lead to more serious health problems, such as liver, kidney, and nervous system damage, as well as an increased risk of cancer. Therefore, in this environment, it is very necessary to choose to use a VOC gas detector.