Circuit Breaker Information
- Model: ATOCLXB4-13
- Rated Current: 13A
- Rated Voltage: 230/400V AC, 50Hz/ 60Hz
- Number of poles: 4 pole
- 10 kA short circuit breaking capacity
- Accordance with IEC standard
- Possibility for locking the toggle in ON or OFF position
- Three different trip characteristics, including B, C and D curves, give you the ability to configure the exact protection scheme you required
Miniature circuit breaker is ideal for the protection of circuits in industrial, commercial, and residential sectors, and ensures the following functions: Protection against short-circuit and overload currents, isolation, protection of persons against indirect contact.
Technical Data
Standard Certifications |
IEC |
UL1077 |
Electrical Parameters |
Height |
86 mm |
Width |
18 mm per pole |
Mounting |
DIN Rail |
Rated Current (In) |
1A, 2A, 3A, 4A, 6A, 10A, 13A, 16A, 20A, 25A, 32A, 40A, 50A, 63A (Available) |
Number of poles |
1P, 2P, 3P, 4P (Available) |
Rated Voltage (Ue) (Optional) |
240/415V or 230/400V |
277/480V |
Rated Insulation Voltage (Ui) |
500V |
Rated Frequency |
50Hz/60Hz |
Short Circuit Interrupting Capacity (Optional) |
6/10KA |
5KA |
Trip Characteristic (Optional) |
B Curve (3-5In) |
B Curve (4In) |
C Curve (5-10In) |
C Curve (7In) |
D Curve (10-20In) |
D Curve (14In) |
Mechanical Parameters |
Electrical Life |
8000 times |
Mechnical Life |
10000 times |
Protection Degree |
IP20 |
Calibration Temperature |
30℃ |
Operating Temperature |
-5℃~+40℃ |
Storage Temperature |
-25℃~+70℃ |
Tightening Torque |
22 Ib-in (2 Nm) |
Terminal Size Acceptability–Min/Max |
2.5 mm2(12 AWG) / 25mm2(3 AWG) |
Circuit Breaker Dimension (Unit: mm)
Details
Tips: What is a moulded case circuit breaker?
The moulded case circuit breaker is also named as the equipment-type circuit breaker. The moulded case refers that the plastic insulator is used as the enclosure of the equipment. All components are sealed in the plastic enclosure, so as to isolate the conductors and the grounding metal parts. The moulded case circuit breaker can cut off the current automatically when the current exceeds the tripping setting. Because the structure is very compact, the moulded case circuit breaker is basically unable to be repaired.
The moulded case circuit breaker equips the contact, arc extinguish chamber, release and operating mechanism and so on in one plastic enclosure. Normally, maintenance is not considered. It is suitable to be used as the protective switch of the branch. The overcurrent release has thermomagnetic type and electronic type. Usually, the thermomagnetic moulded case circuit breaker is the non-selected circuit breaker, which only has the overload long time delay protection and short-circuit instant protection. However, the electronic moulded case circuit breaker has four protective functions, which are respectively: Overload long time delay, short-circuit short delay, short-circuit instant and grounding fault. Some new promoted electronic moulded case circuit breakers still have the function of regional selective interlock. Most of the moulded case circuit breakers are in manual operation while some are also equipped with the motor operation mechanisms.