10 HP portable water chiller machine for sales, 8 ton refrigerating capacity, works in three-phase four wire 50Hz or 60Hz power supply, 240V/ 400V/ 480V AC voltage are optional. It is widely used in industrial injection molding machines, film-blowing machines, laser cutting, chemical and pharmaceutical fields, etc.
Features
- Adopted high-quality compressors and pumps to ensure safe & quiet running, power saving and durable service life.
- Employed microcomputer with easy operation which can control the temperature within 3℃ to 45℃ precisely.
- Unique design for condenser and heat-dispersion unit results in excellent heat-exchange effect.
- Equipped with electrical current overload protection, high & low-pressure switch, and electrical timer delay safety device. It will alarm to display faulty when any malfunction occurs.
- Built-in stainless steel insulated water tank, durable and easy to clean.
- Complete safety devices including power reverse phase, power short phase and anti-freeze protection.
- Ultra low-temperature type of chiller can reach below -60℃.
Parameter
Model |
ATO-LC10A |
Cooling Capacity |
8 ton |
Number of Compressors |
2 |
Compressor Total Power |
10 HP |
Refrigerant |
R22 / R407C (Optional) |
Evaporator Type |
Spiral type / Tube-in-shell type (Optional) |
Condenser Type |
Finned |
Cooling Type |
Air-cooled |
Number of Fans |
2 |
Single Fan power |
0.25kW |
Number of Cooling Water Inlet/Outlet |
1 group |
Cooling Water Inlet/Outlet Size |
DN40 |
Water Tank Capacity |
145L |
Pump Power |
1 HP |
Pump Flow |
200L/min |
Pump Lifts |
13M |
Power Supply |
3-phase 4-wire AC 208V/60Hz, 220V/60Hz, 240V/60Hz, 380V/50Hz, 400V/50Hz, 415V/50Hz, 480V/60Hz (Optional) |
Control Voltage |
1-phase AC 220V (L+N) |
Total Power |
8.8kW |
Wires Specifications |
4x6mm2 |
Certification |
CE |
Dimension |
L*W*H=1500*730*1400mm |
Net Weight / Gross Weight |
450kg / 500kg |
Shipping Way of ATO Water Chiller
Just confirm the shipping way by email when place your order.
1. Ship by Air: The compressed refrigerant inside the chiller is a dangerous item with the possibility of explosion, so it needs to release the compressed refrigerant before transportation. (It means that water chiller without refrigerant when choosing this shipping way. After the machine arrives at your destination, you need to add refrigerant by local professionals, the process is as simple as adding refrigerant for ordinary air conditioners). Delivery time is about 15-30 days.
2. Ship by Sea: The transportation time is longer (about 40-55 days), and there is no need to add refrigerant after the equipment arrives at the destination.
Note:
1. The "cooling capacity" is tested based on the inlet and outlet water temperature of freezing is 12℃/7℃, and the inlet and outlet water temperature of cooling is 30℃/35℃.
2. Working temperature range: Chilled water temperature range is 5℃-35℃, inlet and outlet water temperature difference is 3℃-8℃, and condensation temperature not higher than 35℃.
3. Conversion of units: 1 ton cooling capacity=3024kcal/hr, 1kcal/hr=3.969BTU/hr, 1HP=0.735kW=2580kcal/hr
Water Chiller Structure Diagram
① |
Compressor |
② |
High-pressure gauge |
③ |
Condenser |
④ |
Dry filter |
⑤ |
Expansion valve |
⑥ |
Water supply |
⑦ |
Evaporator |
⑧ |
Low-pressure gauge |
⑨ |
Water tank |
⑩ |
Drain |
⑪ |
Refrigerated water |
⑫ |
Pump |
Tips: Can an industrial water chiller be cleaned with acid?
In normal applications, the chiller requires regular and scientific cleaning, which is also an indispensable part of maintenance. Mainly condensers, evaporators, various pipes, etc., especially the condensers and evaporators of water-cooled type chiller, must be regularly cleaned.
Pickling can be applied as a cleaning method. However, the degree of dilution of the acid solution and the type of acid solution need to be considered. Basically, almost all condensers can be cleaned using acid. In addition, it is necessary to consider whether the components of the water chiller to be cleaned are a certain part or the entire cycle operation system. These two aspects are completely different.
In case of cleaning the circulating operation system, it is necessary to ensure that the system is completely closed, and connect the cleaning pump, liquid distribution tank and relevant valves of the refrigerator. If it is cleaned separately, it is necessary to remove the condenser, and then add the diluted acid into it. It must be filled to achieve the corresponding cleaning effect. The reason why it is necessary to clean the chiller is that there are many parts in the chiller that will affect the normal operation of the whole water chiller.