    10 Tips for Installing Circuit Breaker

    Whether low-voltage circuit breakers are installed properly, which will directly affect its performance and safety. Generally pay attention as follows:

    1. Before installation, the technical parameters listed on the nameplate of the low-voltage circuit breaker should be checked for compliance with the requirements.
    2. Low voltage circuit breakers should be installed vertically, and the wired in front of the board are allowed to be mounted on metal brackets or metal backplanes, but the low-voltage circuit breakers that are wired behind the board must be mounted on the insulating base plate. The bracket or bottom plate of the fixed low-voltage circuit breaker must be flat to prevent damage to the insulating base when the screws are tightened. In order to prevent accidents caused by arcing, the copper busbar of the low-voltage circuit breaker should be packed with 200mm insulation or phase-interval arc plate from the insulation base.
    How Does a Transformer Work?

    How does a transformer work? Transformers mainly applies electromagnetic induction principle to work, the working principle details are as follows: When the primary side of the transformer is applied with the alternating voltage U1 and the current flowing through the primary winding is I1, then the current will generate alternating magnetic flux in the iron core to generate electromagnetic connections between the primary winding and the secondary windings.

    Using VFD for single phase motor

    Variable Frequency Drive (VFD), aka variable speed drive (VSD), generally it's using for controlling 3-phase AC motor in variable speeds. It's important to know, control 1-phase motor speed by a VFD may cause overheat of the motor, as well as the service life. It's recommended to upgrade the motor to three phase AC motor, which you can also connect the 3-phase motor to single phase power supply by using a single phase to three phase VFD, then control the speeds. Anyway, in technical it's possible to use a VFD for single phase motor speed controls, here ATO will show you details about running a single phase motor on a VFD.
    ATO Single Phase VFD

    Brushless DC Motor, How it works?

    Brushless DC motor consists of the motor and drive, is a typical mechatronic product. The stator windings of the motor are mostly made using three-phase symmetrical star connection, which is very similar to the three-phase asynchronous motor. Magnetically charged permanent magnets are attached to the rotor of the motor. In order to detect the polarity of the motor rotor, a position sensor is provided in the motor.

    Linear vs. Switching Power Supply

    Power supply is an important part of the circuit design, and the stability of the power supply determines the stability of the circuit to a large extent. Linear power supply and switching power supply are two common power supplies, and they have a great difference in the principles which determine the difference between the two applications.

    How to Wire a Shunt Capacitor?

    For wirings of three phase shunt capacitors or three phase capacitor banks composed of three single phase shunt capacitors, the most commonly used are star and triangle wirings. Star wiring includes single star wiring and double star wiring while triangle wiring includes single triangle wiring and double triangle wiring. The double triangle wiring is gradually eliminated due to complicated wiring and high cost. Low voltage shunt capacitors mostly use triangular wiring and high voltage shunt capacitors, especially for high voltage shunt capacitors with large capacity, mostly use star wiring.

    What is a Self-healing Low Voltage Shunt Capacitor?

    Self-healing type low voltage shunt capacitor is suitable for the AC power system with working frequency 50Hz or 60Hz, rated voltage 1000V and below and is connected in parallel with load, in order to improve the power factor of system and reduce line loss, improving the voltage quality. It is widely used to improve the efficiency of power supply equipment, local compensation of the inductive equipment such as motor and transformer and electric furnace, electric traction engine, UPS systems and power system harmonic filtration and other aspects.

    How Does VFD Work on Air Compressor?

    It is found that the speed of air compressor motor is proportional to the actual consumed power of the air compressor. Therefore, it is necessary to reduce the motor speed in order to reduce the actual consumption of the air compressor. The use of VFD in air compressor system can realize the real time control of motor speed (output power) without changing the air compressor motor torque through the accurate coordination of electrical control and frequency control in the air compressor system. To change the compressor speed to respond to the system pressure changes and to maintain stable system pressure can realize the output of high quality air pressure according to demand.

    Why You Need a Surge Protection Device?

    When a current spike or voltage surge suddenly occurs in an electrical circuit or a communication line due to external interference like lightning, surge protection device (SPD) can conduct the shunt in a very short time, thereby avoiding the damage of the surge to other equipment in the circuit. It is an indispensable device for lightning protection in the electronic equipment. But some people are still wondering why we need it, or whether need it when we have other lightning protection device? The following FAQ will give your answer for "Why you need a surge protection device".

    Single Stage vs. Two Stage Compression of Piston Air Compressor

    In the actual use of some low pressure and medium pressure piston type portable air compressor, the two stage compression is often used. The intermediate cooler is set. After the cooling of high temperature air discharged from single stage compression, it is then inhaled into two stage cylinder for two stage compression so as to reach the required pressure. Adopt two stage compression, because if use single stage compression to obtain higher air pressure, the pressure ratio (the ratio of the exhaust pressure and suction pressure) is too large, so that the compression process.

    How to calculate safety distance of safety light curtain?

    In practical application, after human body intrudes into the range of safety light curtain, besides that safety light curtain needs certain response time, the machine also needs certain braking time. Therefore, to guarantee personal safety of operators, installation position of safety light curtain must meet requirements of safety distance. Otherwise, there is still the possibility of an accident.

    Selecting the Right Type of Stepper Linear Actuator

    Generally speaking, one of the commonly used methods to achieve precise linear positioning is to make a set of linear positioning system by pairing the motor with the sliding bar. Here we will discuss several different ways to create a linear actuator by using the sliding bar and stepper motor. The stepper motor is the most commonly used selection in the application of motor control because if the operation is correct, it is an economic solution that can achieve accurate positioning without the need of position feedback.
    Stepper linear actuator can be divided into three types, external shaft type, non-captive shaft type and captive type.

    Short circuit, overcurrent and overload protection of electrical device

    All electrical equipments have their rated power. It is called overload when they surpass the rated power, and protection to the status is called overload protection. Protection to prevent internal short circuit of electrical equipment is called short circuit protection and zero-pressure is also called no-voltage protection. When there is power failure, circuit with the functions mentioned above will stop automatically and electric equipment will not start automatically when power is supplied next time. the purpose of the function is to prevent operating personnel forget cut off power source when there is power failure and electric equipment operate automatically next time when there is power and thus cause accidents. General contractor-controlled circuit has this function.

    How to Select a Contactor?

    As equipment to disconnect load power, selection of contactor should meet requirements of controlled equipment. Except that the rated operational voltage is the same with the rated operational voltage of controlled equipment, load power, usage category, control mode, operation frequency, working life, installation method, installation dimension and economy of controlled equipment are the basis of selection. How to choose a right contactor? The principles are as follows:

    Linear Motors Application Guide

    Stator of linear motor has a relatively strong magnetism, thus there will be some specific problems during application. Therefore, proper solutions to the problems are the key to success application, and the following aspects should be concerned in specific application:
    Guarantee mounting dimension between active cell and stator
    The gap between active cell and stator of linear motor is one important parameter, and any small changes can cause great changes of property of motor. Over big gap can directly affect output of linear motor; while over small gap can possibly cause damages to motor since it absorbs other things. Therefore, in installation, it must strictly control to guarantee normal operation of motor.

    Solenoid Valve Installation & Maintenance

    Solenoid valve is one of the most commonly used valves in automatic control system. It is favored by users because it is cheap, simple to operate, convenient and reliable, which can directly receive switch signals of PLC or DCS. Of course, only when it is used properly can the solenoid valve play its full role. Here are some tips in the installation and maintenance of solenoid valves for your reference.
    Installation

    • First check whether the solenoid valve is consistent with the selection parameters, such as power supply voltage, medium pressure, pressure differential etc. If the voltage of power supply is chosen wrongly, it will burn the coil. Generally, the power supply voltage should meet the fluctuation range of rated voltage: AC +10%~-15%, or DC +10%~-10%. Besides, the coil components should not be disassembled normally.
      ...
    What is the harm of transformer three-phase imbalance?

    Three-phase imbalance means that inconsistent amplitude of three-phase current (or voltage) in electrical power system and that amplitude difference surpasses the specified range.
    Unbalanced current of transformer refers to current difference of three-phase transformer windings. The current difference is mainly caused by different three-phase load. Asymmetry of load gives rise to asymmetry of three-phase current which flow through transformer. And current asymmetry causes asymmetry of three-phase impedance drop of transformer, thus three-phase voltage of secondary side is asymmetric, which will do harm to transformer and electric equipment.

    Solenoid Valve Troubleshooting

    Solenoid valve is a basic component of automation to control the fluid, which widely applied both in the industry and in our daily life. Now and then, this small valve encounters some problems, which further affects the normal operation of the whole equipment. So, it would be better to learn some common problems of solenoid valve and know how to trouble shoot them. Here are some common problems occurring with solenoid valves for your reference.

    • Solenoid valve doesn’t work after energized.
    • The valve cannot be closed.
    • There is a leakage inside or outside the solenoid valve.
    • There is a noise after the valve power on.
    DC Contactor Price List

    DC contactor is mainly used to control the DC circuit, it has no impact on the starting current, and will not produce iron core impact, so the service life is long, suitable for frequent start and stop occasions. ATO provides a wide range of DC contactors including universal DC contactors, high voltage DC contactors and DC reversing contactors. Rating current of them from 30 amps to 600 amps, available with 12V, 24V, 48V DC coil. Look at the price of ATO DC concactors listed in the table below, it's cheaper for you to get one from us.

    Direct Acting vs. Pilot Operated Solenoid Valve

    The solenoid valve is one of the products for fluid control automation. According to the start-up working model of the solenoid valve, it can be divided into the most frequently-used two categories: pilot-operated solenoid valve and direct acting solenoid valve. However, if not choose the right one, it easily causes the solenoid valve does not work. Meanwhile, it will somewhat affect the safety of the application. Then, how to distinguish the difference between pilot-operated and direct acting solenoid valve? How to choose the right one for the better application? The following will give you some enlightenment.