Existing reviews of Micro Load Cell, S Type, 5N/500N/1000N, 1kg/10kg/30kg/200kg
More information in load cell application
Hey
I'm looking at the Micro Load CELL, S- Type, 5N,500N,1000N.
I want to ask you if you can supply me with a dynamic response, frequency response, and any other relevant information related to its performance in dynamic force measurement applications.
From:
sini
|
Date:
20/07/2023
Was this review helpful?
Yes
No
(0/0)
Unfortunately, our load cells can only measure under static conditions, and dynamic measurements may not be accurate.
Where should I connect the yellow wire?
I purchased this load cell and display controller for load cells in your website.
I can read Chinese, but the manual only introduce how to use the controller, not how to wiring. The diagram is very helpful, and my last question is where should I connect the yellow wire (shield) to? There are five wires from the load cell (red, black, green, white, yellow).
Thanks.
From:
dylan
|
Date:
01/03/2023
Was this review helpful?
Yes
No
(0/0)
This yellow line (shielding line) of the sensor does not need to be connected.
For the other four lines, please follow the picture description.
Please feel free to let us know if you have any further questions.
I have a problem with the load cell, please provide a solution.
Our application weighs points at a time and we need a controller with 6 channels to connect all 6 load cells in the same controller to identify independence load cell weight and consolidated weight. Please provide a solution for the same.
From:
Christopher
|
Date:
24/01/2022
Was this review helpful?
Yes
No
(0/0)
No controller can be connected to 6 sensors at the same time. But you can use a junction box to measure the consolidated value.
Distance between mincro load cell and transmitter
In short, can I use your load cell amplifier for a concrete batching plant where the load cell may be placed about 40 meters far from the amplifier where the environment may produce a lot of noise. Your amplifier lacks cable shield input and four load cells tied together for single amplifiers.
From:
Dorothyg
|
Date:
03/11/2021
Was this review helpful?
Yes
No
(0/0)
The distance between the transmitter and the load cell can be up to 50 meters, and shielding cable can also be used, so the length of 40 meters is okay.
We cannot confirm the influence and interference of a lot of noise on the sensor signal.
Does ATO provide wireless load cells?
Do you provide wireless load cells?
From:
Chadm
|
Date:
10/05/2021
Was this review helpful?
Yes
No
(0/0)
Yes, of course. just need to confirm which model of our load cell you are intersted in, as some supported and someother not.
Does the Bridge (Excitation) Voltage mean the amount of volts I need to in order to turn on the load cell?
From:
Cole
|
Date:
08/04/2020
Was this review helpful?
Yes
No
(0/0)
Yes, the load cell bridge (excitation) voltage can also be called working voltage, input voltage or supply voltage. Because the main circuit of load cell is the Wheatstone bridge. For our load cell, the excitation voltage can be DC 5-15V.
Load more reviews...