Close
(0) Shopping cart
You have no items in your shopping cart.
Shopping Categories
    Filters
    Preferences
    Search

    RO Water Purification System, <20ppb TOC, Type 1 & 3

    5 out of 5 based on 1 reviews | Write a review
    $4,919.23
    Lab reverse osmosis deionized water purification system on sale, tap water filtered to Type I and Type III ultrapure water, 18.2 megohm resistivity and less than 20ppb TOC, applied to atomic absorption/ atomic emission spectroscopy, toxicity test, quantitative analysis of trace element, buffer solution, GC, IC, HPLC etc.
    *
    *
    SKU: ATO-WPS-Moatom510
    30-day Returns
    Free Shipping
    Delivery date: 6-12 days

    Low cost 10L per hour laboratory water ultrapurifier with 30L tank and metal plate housing, IC microcomputer intelligent control/Full automatic PLC control, ultrapure water & pure water from one unit.

    Specification

    Model Moatom510s/ 520s/ 530s Moatom510d/ 520d/ 530d
    Process Single pass RO system Double pass RO system
    Output of pure water ≥10L/H ≥10L/H
    Output of ultrapure water ≥ 1-1.5L/min ≥ 1-1.5L/min
    Resistivity at 25℃ 18.25MΩ.cm 18.25MΩ.cm
    Conductivity at 25℃ ≤10μs/cm ≤5μs/cm
    TOC < 20ppb < 20ppb
    Pyrogens < 0.02EU/ml < 0.02EU/ml
    Absorbance (254nm,1cm optical distance) ≤ 0.001 ≤ 0.001
    Reactive Silica (SiO2) < 0.01ppm < 0.01ppm
    Heavy metal < 0.01ppm < 0.01ppm
    Electrical requirements 220V (230V, 240V) 50Hz
    Power ≥100W ≥150W
    Dimension (L/W/H) 340*550*530mm 340*550*530mm
    Weight ≥30KG ≥39KG
    Tank capacity  30L

    Note: The model end with 's' has single stage RO module, suitable for feed water inlet TDS<200PPM. Model end with 'd' have double stage RO module, suitable for feed water inlet 200ppm<TDS<400ppm. If feed water inlet TDS>400PPM, suggest an additional industrial type softener.

    Product Features
    Power-on self-test, water shortage protection alarm, power-off protection.
    Built-in RO membrane anti-scaling program, RO membrane manual cleaning button.
    Built-in ultra-pure water automatic cycle program, manual cycle button to maintain ultra-pure water quality.
    On-line monitoring of water resistance, real-time display of system operating status and warnings.
    With water quality and water production upgrade function.
    Intelligent large-capacity ultra-purification column with built-in RFID chip.
    Digital display the time of regular intake or the water pressure.
    Easy to clean, disinfect and drain off waste water.

    Lab Test and Corresponding Water Type List

    Test Name Type III Water Type II Water Type I Water
    Lab glassware washing    
    Hydroponics    
    Sterilizer use water    
    Gas generator use water  
    Conventional test    
    Reagents/ drugs preparation, dilution    
    Feed water for ultrapure water    
    IC    
    LC/LC-MS    
    HPLC    
    AAS    
    ICP/ICP-MS    
    GC/GC-MS    
    Trace analysis    
    TOC analysis    
    Organic analysis    
    Inorganic analysis    
    Environmental analytical test    
    Microelectronics parts cleaning    
    Precision instrument use water    
    Analytical reagent/ drugs preparation, dilution    
    Mass spectrometry    
    PCR application/analysis    
    DNA/RNA research    
    Proteomics research    
    Plant and animal cell culture    
    Toxicity analysis    
    Microbiology experiment    
    Immunological experiment    
    Biochemistry experiment    
    Serum test    
    IVF    

    Main Consumable List (A water purification system is equipped with a set of consumables. If you want to buy some of the following consumables, contact us now.)

    No. Name Specification Lifespan
    1 PP filter 1st stage, 10”/20” (5μm) 3-6 months
    2 Activated Carbon filter 2nd stage, 10”/20” 6-12 months
    3 Softener filter 3rd stage, 10”/20” 6-12 months
    4 Precision filter 4th stage, 10”/20” (1μm) 10-12 months
    5 RO membrane 75g/300g 1-2 years
    6 Ultra purification resin column   1 year
    7 Micro filter 0.22μm 1 year
    8 UV lamp 185/254nm 8000 hours
    9 Pure water tank 30L, 80L, 120L  

    Tips: Operation process of ATO laboratory ultrapure water system
    1. Check whether the water source stainless steel ball valve switch is open and the power cord is connected.
    2. Press the power button. At this time, the “system water making” indicator lights up and starts to work normally.
    3. Every 2-3 days, please press the "System Wash" button before taking water after booting. At this time, the system is manually cleaned for 1-2 minutes. After washing, press the "System Wash" switch again.
    4. Please keep the plastic ball valve on the water storage bucket in the same direction as the pipeline connection. At this time, do not turn off the ball valve switch. Do not twist the vacuum plug on the bottom of the water storage bucket, otherwise the water storage bucket will be scrapped.
    5. Pre-processor cleaning: After a period of time when the equipment is in use, the white PP polymer fiber filter starts to change from white to yellow. At this time, remove the bucket of the preprocessor with a special wrench equipped, take out the fiber filter element and wash it with high-pressure tap water. When reinstalling, check whether the plastic pad inside the bucket is properly mated, and make sure that the bucket does not leak after installation. Activated carbon cleaning is the same method. Under normal circumstances, the cleaning time is 2-3 months / times.

    Existing reviews of RO Water Purification System, <20ppb TOC, Type 1 & 3
    I’m loving it so far
    We’ve had this water filter for about 3 months. This system removes chlorine and most all toxins that is in our tap water. It tastes great and we now drink water almost exclusively. We LOVE it.
    From: Eric | Date: 08/11/2023
    Was this review helpful? Yes No (0/0)
    Load more reviews...
    Write your review for RO Water Purification System, <20ppb TOC, Type 1 & 3
    • Only registered users can write reviews
    • Bad
    • Excellent