    Thermocouple/RTD signal conditioner, Analog Output 4-20mA/0-10mA/0-5V

    $110.58
    Signal isolator ATO-SIGNI-503H series is a special thermocouple/RTD signal conditioner. The input signal can be thermocouple K/B/S/E type and RTD Pt100, and the output signal can be current 4-20mA/0-20mA and voltage 0-5V/1-5V/0-10V. Signal isolator has pluggable terminals, 13mm thickness, minimum resolution 0.1℃ and DIN rail installation mounting groove.
    *
    *
    *
    *
    *
    *
    *
    *
    *
    *
    *
    *
    *
    SKU: ATO-SIGNI-503H
    30-day Returns
    Free Shipping
    Delivery date: 6-12 days

    This SKU ATO-SIGNI-503H is out of stock.
    We recommend you another signal isolator ATO-SIGNI-402E, which has up to 2 input channels & 2 output channels, input signal 4-20mA, 0-20mA, K, B, S, E, Pt100 and output signal 4-20mA, 0-20mA.


    Thermocouple/RTD signal conditioner can input signal of K/B/S/E/PT100 and output signal of 4-20mA/0-20mA/0-5V/0-10V/1-5V.

    Specification:

    Model ATO-SIGNI-503H
    Weight 130g
    Dimension 108*13*121.2mm
    Input signal *  K, B, S, E, Pt100
    Output signal * 4-20mA, 0-20mA, 0-5V, 0-10V, 1-5V
    Load impedance RL≤400Ω (current output); RL≥250KΩ (voltage output)
    Number of input & output channels * 1 input channel & 1 output channel, 1 input channel & 2 output channels, 2 input channels & 2 output channels
    Power supply DC 20-30V
    Power dissipation 1 output channel: ≤1W, 2 output channels: ≤1.4W
    Transfer accuracy 0.2%FS±1 byte
    Minimum resolution 0.1℃
    Temperature range of cold junction compensation -10~+50℃
    Accuracy of cold junction compensation ±1℃
    Response time ≤50ms
    Insulation resistance ≥100MΩ at DC 500V
    Dielectric strength 1500Vrms (1min, no-spark)
    Temperature drift 0.0075%FS/℃
    Working temperature -10~+50℃
    Relative humidity 25%~85%RH
    Storage temperature -10~+60℃
    Electro magnetic compatibility IEC 61326-1
    Installation 35mm DIN rail

    Dimensional drawing (unit: mm):
    Thermocouple/RTD signal conditioner dimension
    Wiring diagram:
    Thermocouple/RTD signal conditioner wiring diagram

    Write your review for Thermocouple/RTD signal conditioner, Analog Output 4-20mA/0-10mA/0-5V
    • Only registered users can write reviews
    • Bad
    • Excellent
    Customers who bought this item also bought

    Isolated DC Voltage Sensor 10mV to 1000V, Power Supply DC 12V/24V

    $141.96
    SKU: ATO-VOS-DC1000
    DC voltage sensor uses modulation and demodulation technology to achieve input/output/power supply isolation. Isolated voltage transducer has measuring range from DC 10mV/50mV/75mV/5V/150V/300V/500V to 1000V, supply voltage DC 12V/24V, accuracy 0.2%FS, output signal 0-5V/0-10V/0-20mA/4-20mA and strong anti-interference capability. DC voltage sensor is widely used for voltage isolated measuring and control, such as electric power, remote monitoring, medical equipment, etc.

    Current Sensor AC/DC 0.1mA/1mA/5mA/10mA/20mA/50mA/0.2A/0.5A/1A to 5A

    $126.37
    SKU: ATO-CUS-ACDC5
    Current sensors are AC/DC universal current sensors, with a low current measuring range from milliamp current 1mA to 5A. AC/DC current sensors adopt linear photoelectric isolation or modulation and demodulation principle, fast response, 0.5%FS high accuracy, good stability, small size, light weight, input current terminal connection, DIN rail installation. Isolated current sensors are widely used for AC sine wave current or DC bidirectional current measurement.