    Portable Sulfur Hexafluoride (SF6) Gas Detector, 0 to 1000/2000/3000 ppm

    $1,589.52
    SF6 leak detector for sale online, providing a built-in micro pump, high precision sensor, sound, light &vibration alarm and 0 to 1000ppm/2000ppm/3000ppm measurement range. It is a portable single gas detector, best for Sulfur Hexafluoride (SF6 ) gas detection and monitoring.
    *
    *
    *
    SKU: GD200-SF6
    30-day Returns
    Free Shipping
    Delivery date: 6-12 days

    Buy a portable gas detector for monitoring SF6 gas concentration. With a high-precision sensor, 0 to 1000/2000/3000 ppm measuring range and clear LCD display, this handheld SF6 leak detector is mainly used in power facilities, manufacturing and industrial processes to detect and repair leaks to ensure equipment safety and environmental protection.

    Features

    • LCD dot matrix display, direct readout of gas type, unit, concentration, local time, etc.
    • Support English/Chinese operation, easy to shift.
    • Gas concentration unit PPM and mg/m3 can be shift quickly.
    • Built-in micro-sampling pump, 10 grades of suction are available.
    • Explosion-proof certification

    Gas Detector Functions

    • With self-calibration and zero calibration functions, makes the detection more accurate and reliable.
    • One key to restore factory setting, free from maloperation.
    • With temperature and pressure compensation, able to realize the compensation for the gas concentration under different temperature and pressure environments.
    • Two-stage alarm with sound and light, and alarm point is settable.
    • Rechargeable lithiumpolymer battery with large capacity.
    • High-strength special engineering plastic housing, with anti-slip, waterproof, dustproof and explosion-proof.

    Specifications

    Model GD200-SF6
    Sampling Method Pumping suction, flow rate can be up to 750ml/min
    Detection Principle Electrochemistry
    Gas Sulfur Hexafluoride (SF6)
    Range (Optional) * 0-1000ppm, 0-2000ppm, 0-3000ppm
    Resolution 1ppm
    Accuracy ≤±3% F.S.
    Response Time ≤10s
    Repeatability ≤±1%
    Recovery Time ≤10s
    Linearity Error ≤±1%
    Zero Shift ≤±1% (F.S./year)
    Data Logging (Optional Function) High speed data transmission by USB, available for data downloading and printing (The built-in IC card has about 2G memory, which can record 100,000 sets of data.)
    Alarms Sound, light and vibration
    Display LCD dot matrix display
    Language Chinese/English
    Battery 3.7V rechargeable lithium battery, 3.7 Watt
    (Charger included: Input AC 100-240V 50/60Hz with optional USA, Europe or UK plug)
    Operating Time 100h (Pump off)
    Communication Mini USB interface supports standard MODBUS communication protocol
    Explosion-proof Grade Ex ia IIC T4
    Case Material ABS+PC
    Protection Grade IP66
    Certification CE, ATEX
    Operating Temperature -20℃~50℃
    Operating Humidity 0~95%RH (non-condensing)
    Operating Pressure 0.8~1.2bar
    Dimension 205*75*32mm
    Weight 300g
    Warranty 12 months
    Extension Probe About 480mm (Total Length), About 300mm (Probe Head)
    Accessories (Optional) Calibration kit - gas pressure regulator (calibration gas cylinder NOT included)

    • Body Material: Stainless steel
    • Input Range of Pressure Gauge: 0-25MPa
    • Output Range of Pressure Gauge: 0-0.6Mpa
    • Gauge Class: 2.5
    • Input Pressure: ≤15MPa
    • Output Pressure: ≤0.45MPa
    • Rated Flow: 0.6 m3/h
    • Connection: Inlet: W21.8-14 teeth/inch (levorotation, dextrorotation) ; Outlet: Ф6 flexible tube

    Note:
    * If you need a SF6 gas detector with other measuring ranges unlisted in above table, please contact us to inform your operating environment, so as to help you choose an appropriate one for your application.
    * We also provide other common gas detectors, and you can refer to ATO Gas Detector Catalog to get the specific gas type and measurement range. If you have any questions, please feel free to contact us.

    *** Other Common Gases and Ranges Available for Portable Gas Detectors

    Gas Type Measure Range Resolution
    Ammonia (NH3) 0-10/20/50/100/200/500/1000/2000/5000ppm 0.01ppm/0.1ppm/1ppm
    Benzene (C6H6) 0-1/5/10/20/50/100/200/500/1000/2000/5000ppm 0.001ppm/0.01ppm/0.1ppm/1ppm
    Carbon Dioxide (CO2) 0-1000/2000/5000/10000/20000/50000 ppm, 0-10%/20%/30%/50%/100%VOL 1ppm, 0.01%VOL
    Carbon Monoxide (CO) 0-10/20/50/100/500/1000/2000ppm 0.001ppm/0.01ppm/1ppm
    Chlorine (Cl2) 0-5/10/20/50/100/200ppm 0.001ppm/0.01ppm/0.1ppm
    Chlorine Dioxide (ClO2) 0-10/20/50/100ppm 0.001ppm/0.01ppm/0.1ppm
    Ethylene (C2H4) 0-10/20/50/100/500/1000/2000ppm 0.001ppm/0.01ppm/0.1ppm/1ppm
    Flammable 0-100%LEL 1%LEL
    Formaldehyde (CH2O) 0-10/20/50/100/500/1000ppm 0.01ppm/0.1ppm/1ppm
    HC 0-100%LEL 1%LEL
    Hydrogen (H2) 0-10/20/100/500/1000/2000/5000ppm, 0-1%/2%/4%VOL 0.001ppm/0.01ppm/1ppm, 0.001%VOL
    Hydrogen Chloride (HCL) 0-10/20/50/100/200/500/1000/2000ppm 0.01ppm/0.1ppm/1ppm
    Hydrogen Cyanide (HCN) 0-10/20/50/100ppm 0.01ppm/0.1ppm
    Hydrogen Fluoride (HF) 0-1/5/10/50ppm 0.001ppm/0.01ppm
    Hydrogen Sulfide (H2S) 0-5/10/20/50/100/200/500/1000/2000ppm 0.001ppm/0.01ppm/0.1ppm/1ppm
    Methane (CH4) 0-100%LEL, 0-50%/100%VOL 1%LEL, 0.01%VOL
    Methyl Bromide (CH3Br) 0-1/10/20/50/100/200ppm 0.01ppm/0.1ppm/1ppm
    Nitric Oxide (NO) 0-20/50/100/250/500/1000ppm 0.01ppm/0.1ppm/1ppm
    Nitrogen (N2) 0-100% VOL 0.01%VOL
    Nitrogen Dioxide (NO2) 0-20/50/100/500/1000ppm 0.01ppm/0.1ppm/1ppm
    Oxygen (O2) 0-25%/30%/100%VOL 0.01%VOL
    Ozone (O3) 0-5/10/20/50/100/200/500/1000/2000ppm 0.001ppm/0.01ppm/0.1ppm/1ppm
    Phosgene (COCl2) 0-1/5/10ppm 0.001ppm
    Phosphine (PH3) 0-10/20/50/100/500/1000/2000/3000ppm 0.01ppm/0.1ppm/1ppm
    Sulfur Dioxide (SO2) 0-20/50/100/500/1000ppm 0.01ppm/0.1ppm/1ppm
    Sulfur Hexafluoride (SF6) 0-1000/2000/3000ppm 1ppm
    Volatile Organic Compounds (VOC) 0-1/5/10/20/50/100/200/500/1000/2000/5000ppm 0.001ppm/0.01ppm/0.1ppm/1ppm


    Details

    Handheld Ammonia (NH3) Gas Detector Details

    Applications

    HF gas detector applications

    Tips: Why need to detect Sulfur Hexafluoride (SF6) gas?

    • Safety Concerns: SF6 is an asphyxiant, meaning it can displace oxygen in the air, posing a suffocation risk in confined spaces. Prompt detection ensures worker safety in environments where SF6 is used, such as in electrical substations and industrial processes.
    • Environmental Impact: SF6 is a potent greenhouse gas, with a global warming potential approximately 23,500 times greater than carbon dioxide over a 100-year period. Detecting and mitigating SF6 leaks helps in reducing its environmental footprint and aligning with international climate agreements and regulations.
    • Equipment Maintenance: SF6 is commonly used as an insulating and arc-quenching gas in high-voltage circuit breakers and other electrical equipment. Leaks or decompositions can lead to equipment malfunction or failure, causing costly downtime and repairs. Early detection allows for timely maintenance, ensuring operational reliability and longevity of the equipment.
    • Overall, the use of SF6 detectors supports safe working conditions, environmental protection, and efficient maintenance practices, making them an essential tool in industries that utilize this gas.

    Basic Settings of Portable Gas Detector

    This video will show you the basic settings of ATO portable gas detectors including high/low alarm setting, language setting and time setting.

    Calibration of Portable Gas Detector

    This video will show how to calibrate the ATO portable gas detectors.

    Concentration Detection of Pesticides Gas
    Methyl bromide is an organic compound with the chemical formula CH3Br, which is mainly used as a pesticide, fumigant, refrigerant and solvent, and can also be used in organic synthesis.This video will mainly use methyl bromide and CH3Br as examples to introduce the detection of their concentrations.

    How to Detect Hydrogen Sulfide Concentration in the Toilet
    Hydrogen sulfide is a flammable acidic gas that smells like rotten eggs at low concentrations and is very toxic. In actual operation, it is necessary to ensure that the detection equipment or method used can accurately measure the concentration of hydrogen sulfide, and pay attention to safety issues during operation to avoid hydrogen sulfide poisoning.

    How much C2H4 (ethylene) do ripe bananas and apples produce?
    We have various gas detectors such as: CO, O2, O3, H2, NH3, H2S, CH4, Cl2, CH2O, etc, from 0~10000ppm, Industrial or daily use.

    Write your review for Portable Sulfur Hexafluoride (SF6) Gas Detector, 0 to 1000/2000/3000 ppm