Close
(0) Shopping cart
You have no items in your shopping cart.
Shopping Categories
    Filters
    Preferences
    Search

    Active High Voltage Differential Probe

    $2,021.19
    Buy active high voltage differential probe online at an economical price, with bandwidth from 70MHz to 200MHz, and common mode voltage from 700V to 7000V. This active high voltage differential probe is used for measuring high-voltage signals of the oscilloscope with precision and safety.
    *
    SKU: ATO-HVDP-6000
    30-day Returns
    Free Shipping
    Delivery date: 6-12 days

    Active high voltage differential probe is used to measure high voltage signals with precision while maintaining safety. It features active electronics that amplify the signal, allowing it to measure high voltage differences between two points without requiring a direct ground reference.

    Specification

    Model ATO-DP6070A ATO-DP6150 ATO-DP6150A ATO-DP6150B ATO-DP6280 ATO-DP6700 ATO-DP6700A
    Bandwidth (-3dB) 100MHz 70MHz 100MHz 200MHz 100MHz 70MHz 100MHz
    Rise Time ≤3.5ns ≤5ns ≤3.5ns ≤1.75ns ≤3.5ns ≤5ns ≤3.5ns
    Accuracy ±2%
    Range Selection (Attenuation Ratio) 10X/100X 50X/500X 100X/1000X
    Maximum Differential Measurement Voltage (DC + Peak AC) 10X: ±70V 50X: ±150V 100X: ±280V 100X: ±700V
    100X: ±700V 500X: ±1500V 1000X: ±2800V 1000X: ±7000V
    Common Mode Voltage (DC + Peak AC) ±700V ±1500V ±2800V ±7000V
    Maximum Input Voltage to Ground (Vrms) 450V CATⅡ 600V CATⅢ 1000V CATⅢ
    600V CATⅠ 1000V CATⅡ 2300V CATⅠ
    Input Impedance Single-Ended to Ground 2.5MΩ 5MΩ 20MΩ
    Two Input Terminals 5MΩ 10MΩ 40MΩ
    Input Capacitance Single-Ended to Ground <4pF <5pF
    Two Input Terminals <2pF <2.5pF
    CMRR DC >80dB
    100kHz >60dB
    1MHz >50dB
    Noise (Vrms) 10X: <20mV 50X: <50mV 100X: <100mV 100X: <200mV
    100X: <120mV 500X: <300mV 1000X: <600mV 1000X: <1.2V
    Overload Indication Voltage Threshold 10X: ≥70V 50X: ≥150V 100X: ≥280V 100X: ≥700V
    100X: ≥700V 500X: ≥1500V 1000X: ≥2800V 1000X: ≥7000V
    Delay Time Probe Host 9ns
    BNC Cable
    (1m)
    5ns
    Bandwidth Limit (5MHz) ≥-3dB@5MHz
    Overload Indicator (Red Light) Yes
    Overload Alarm Sound Yes (Optionally Close)
    Auto Save Function Yes
    Bias Adjustable Function Yes (Adjust in Test Mode)
    Terminal Load Requirement ≥100kΩ
    Power Supply USB 5V/1A Adapter
    Safety Compliance EN61010-1: 2010
    EMC Compliance EN61326-1:2013 EN61000-3-2:2006+A1:2009+A2:2009 EN61000-3-3:2013


    Details

    Active high voltage differential probe details

    Maximum Differential Mode Voltage vs. Frequency Curve

    High voltage differential probe differential mode voltage vs frequency diagram

    Tips: What is an active high voltage differential probe?

    An active high voltage differential probe is a specialized instrument used to measure high-voltage signals with high accuracy and safety. It features two input channels that measure the voltage difference between them, rather than referencing a single point to ground. This allows it to accurately capture signals in environments with high common-mode voltages. The probe has built-in amplification and isolation circuitry to handle high voltages safely, protecting both the user and the measurement equipment. It typically connects to an oscilloscope or similar device for signal analysis. The active design enhances accuracy by minimizing noise and distortion, making it crucial for testing and troubleshooting high-voltage systems in power electronics, telecommunications, and other high-power applications.

    Write your review for Active High Voltage Differential Probe
    • Only registered users can write reviews
    • Bad
    • Excellent