Close
(0) Shopping cart
You have no items in your shopping cart.
Shopping Categories
    Filters
    Preferences
    Search

    Handheld Precision Multifunction Calibrator, Output Signal Source

    $412.22
    This handheld multifunction calibrator is a high precision signal source/generator, designed to output variety of signals including DC voltage, DC current, resistance, RTD, thermocouple, pulse frequency, and power distribution, ideal tool for calibrating and troubleshooting detectors.
    SKU: ATO-SIGNAL-LR-C512
    30-day Returns
    Free Shipping
    Delivery date: 6-12 days

    Features

    • Automatic power supply changeover, able to be powered by external AC/DC power supply and switch to batteries powered uninterruptedly without external power supply
    • Battery status monitoring
    • Memory storage up to 64 frequently-used data at request
    • LCD display for multiple types of information about output value, signal type, power supply, memory status and so on
    • Output signal values can be input through numeric keys and adjusted through direction keys.

    Specification

    1. Basic information

    • Model: ATO-LR-C512
    • Power Supply: 4 AA (1.5V) batteries; Power adapter, input voltage 110~220V AC
    • Warm-up Time: 15 minutes recommended
    • Power Consumption: Dependent on the type of output signal and load.
      When powered by 4 AA 1.5V alkaline batteries:
      At 4VDC output/1kΩ load, batteries can last 4 hours.
      At 5VDC output/10kΩ load, batteries can last 21 hours.
      At 24mA output/50Ω load, batteries can last 4 hours.
    • Vibration&Impact: 2g (random), 5~500Hz (tested within 1m)
    • Calibration Period: 1 year recommended
    • Operating Environment: Temperature: 0℃~50℃; Humidity ≤80%RH, non-condensing; Altitude≤2000m
    • Storage Environment: Temperature: -25℃~60℃; Humidity≤90%RH, non-condensing
    • Size: 95×203×40mm
    • Weight: 380g (battery not included

    2. Signal Source Output Accuracy

    Functions Signal Output Range Resolution Accuracy (25℃±10℃) Remarks
    DC Voltage 100mV (-10.00~110.00)mV 10uV ±(0.01%+10uV) /
    1V 0~1.2000V 0.1mV ±(0.01%+0.1mV) Maximum output current: 0.25mA
    10V 0~12.000V 1mV ±(0.01%+2mV) Maximum output current: 2.5mA
    DC Current 20mA 0~24.000mA (Source) 1μA ±(0.02%+2μA) Open-circuit voltage 19V
    -20mA 0~-24.000mA (Sink) 1μA ±(0.02%+2μA) External power supply 5~28V
    Resistance 400Ω 0~400.00Ω 0.01Ω ±(0.015%+0.1Ω) 0.1~0.5mA exciting current (The accuracy hasn’t taken into account the error induced by the resistance of the wires.)
    The maximum extra error is no more than 0.25Ω at 0.1mA exciting current.
    4kΩ 0~4000.0Ω 0.1Ω ±(0.015%+0.3Ω) 0.05~0.3mA exciting current (The accuracy hasn’t taken into account the error induced by the resistance of the wires.)
    The maximum extra error is no more than 0.5Ω at 0.05mA exciting current.
    RTD Resistance Pt100 -200℃~850℃ 0.1℃ -200~0℃: ≤0.3℃ ±1mA drive current for Pt100 and Cu50
    ±0.1mA drive current for Pt1000
    (The accuracy hasn’t taken into account the error induced by the resistance of the wires.)
    0~400℃: ≤0.4℃
    400~850℃: ≤0.5℃
    Pt1000 -200℃~850℃ 0.1℃ -200~100℃: ≤0.2℃
    100~300℃: ≤0.3℃
    300~850℃: ≤0.4℃
    Cu50 -50℃~150℃ 0.1℃ -50~150℃: ≤0.5℃
    Thermocouple R -40℃~1760℃ 1℃ -40~100℃: ≤1.5℃ ITS-90 temperature scale is adopted.
    The accuracy in the table does not include the cold junction compensation error which is less than ±2℃.
    Without cold junction compensation, the reference temperature for the cold junction is 0℃.
    100~1760℃: ≤1.1℃
    S -20℃~1760℃ 1℃ -20~100℃: ≤1.5℃
    100~1760℃: ≤1.1℃
    K -200℃~1370℃ 0.1℃ -200~-100℃: ≤0.6℃
    -100~400℃: ≤0.5℃
    400~1200℃: ≤0.6℃
    1200~1370℃: ≤0.7℃
    E -200℃~1000℃ 0.1℃ -200~-100℃: ≤0.5℃
    -100~600℃: ≤0.5℃
    600~1000℃: ≤0.4℃
    J -200℃~1200℃ 0.1℃ -200~-100℃: ≤0.5℃
    -100~800℃: ≤0.4℃
    800~1200℃: ≤0.6℃
    T -200℃~400℃ 0.1℃ -200~400℃: ≤0.4℃
    N -200℃~1300℃ 0.1℃ -200~-100℃: ≤0.6℃
    -100~900℃: ≤0.5℃
    900~1300℃: ≤0.6℃
    B 400℃~1800℃ 1℃ 400~600℃: ≤1.5℃
    600~800℃: ≤1.1℃
    800~1800℃: ≤0.7℃
    Frequency/Continuous Pulse 100Hz 2.00Hz~99.99Hz 0.01Hz ±0.01Hz Amplitude: 1.00~10.00Vp-p, adjustable, low level 0V;
    Duty cycle: 50%; Load: >100kΩ.
    1kHz 100.0Hz~999.9Hz 0.5Hz ±0.5Hz
    10kHz 1000Hz~10000Hz 100Hz ±10Hz
    Pulse Cycle (Preset Number of Pulses) 100Hz/1kHz/10kHz 10~99,999cycles 1 cycle ±2 pulses Amplitude: 1.00~10.00Vp-p, adjustable, low level 0V;
    Duty cycle: 50%; Load: >100kΩ.
    Contact/OC Switch ON/OFF 100Hz/1kHz/10kHz The accuracy is the same as ones of continuous pulse and pulse cycle. Transistor type: NPN, Vce≤+28V, Ice≤50mA;
    Duty cycle: 50%.
    Output Power Supply 24V / / ±10% Maximum load capacity 25mA, with short circuit protection

    Details

    Handheld Precision Multifunction Calibrator Details

    Tips: Troubleshooting C512 Handheld Precision Signal Source Calibrator
    1. The calibrator cannot turn on or automatically shut down.
    Possible reasons:
    a. Low battery
    b. Poor contact between the plug of power adapter and the socket of the generator
    Troubleshooting:
    a. Replace the 4 AA batteries (1.5V) with new ones.
    b. Ensure the plug is tightly fitted to the socket.

    2. The device displays “ERROR”.
    Possible reasons: Low battery
    Troubleshooting: Replace the 4 AA batteries (1.5V) with new ones.

    3. The signal output is intermittent.
    Possible reasons: Poor contact of the probe
    Troubleshooting: Ensure the probe wire and probe clip is connected well; the probe wire and the output of signal generator are tightly fitted.

    Write your review for Handheld Precision Multifunction Calibrator, Output Signal Source
    • Only registered users can write reviews
    • Bad
    • Excellent
    Customers who bought this item also bought

    Handheld Voltage Current Thermocouple Calibrator, Output Signal Source

    $146.03
    SKU: ATO-SIGNAL-C703
    This handheld calibration tool is a voltage, current and thermocouple signal source/generator, able to output and measure 0-30V, 0-24mV, and 0-100mV voltage signal, 0-24mA and 4-20mA current signal and K, E, J, T, R, B, S, N type thermocouple, easy to use and high accuracy, helpful for testing and calibration in the industry field.