8-pin electromagnetic relay with DPDT contact configuration can be widely used in remote control, electronic equipment, communication equipment, automatic control system and tools etc. Low cost and high quality.
This video introduces the MK 2P-I series electromagnetic relay provided by ATO. With its convenient wiring, rapid reset, durable construction, and consistent performance, this relay promises enhanced safety and efficiency in electric circuit management.
Specification
Basics |
Model |
ATO-MK2P-1 (Relay with Socket) |
Dimension (L*W*H) |
35×35×53mm |
Weight |
76g |
Ambient Temperature |
-25℃~+55℃ |
Terminal Type |
Plug in |
Number of Pins |
8 |
Technical Parameters |
Contact Form |
DPDT |
Contact Material |
Silver alloy |
Contact Capacity (Resistive load) |
10A/250V AC 28V DC |
Coil Power |
DC≤2W, AC≤3.5VA |
Coil Voltage |
Optional: 12V DC, 24V DC, 12V AC, 24V AC, 36V AC, 110V AC, 220V AC |
Pick-up Voltage at 23℃ |
DC≤75%, AC≤80% |
Drop-out Voltage at 23℃ |
DC≥10%, AC≥30% |
Contact Resistance @6V DC 1A |
≤100MΩ |
Dielectric Strength |
Between open contact |
≥1200V AC 50Hz/1min |
Between adjacent contact |
≥1500V AC 50Hz/1min |
Between coil & contact |
≥1500VAC 50Hz/1min |
Leakage current |
≤1mA |
Insulation Resistance (MΩ) |
≥500MΩ at 500V DC |
Service life |
Electrical |
105 Times (Frequency: On 1 Time/1s, Off 1 Time/1s) |
Mechanical |
106 Times (Frequency: 300 Time/1min) |
Note: Here just shows the contact form DPDT, and another contact forms 2NO and 2NC are still available. What's more, please kindly note that other coil voltages are also available(DC: 6-220V; AC: 6-380V). If you have any requirments, please don't hesitate to contact us.
Dimensions & Connection Diagram
Relay Socket Size
Details
Tips: Applications of electromagnetic relays
- Flood alarm: open or close a circuit by changes of water level to realize alarm function.
When the water level exceeds the warning line, the floater will float up. As a result, the circuit will be closed and the electromagnet will attract the armature. Then, alarm indicator is powered on to alarm users.
- Automatic temperature alarm: the level of mercury changes with temperature. Its changes could be used to control opening and closing of the circuit and realize function of the automatic temperature alarm. When temperature rises to a threshold value, mercury in the thermometer will rise to the wire. Mercury is a kind of conductor, so it could be used to close the circuit of the electromagnetic system. As a result, the electromagnet will attract the spring and close the alarm circuit to make it ring up. When temperature falls, mercury in the thermometer will be disconnected from the wire. Consequently, the spring will restore its position and the electromagnetic circuit will be opened to silence the alarm.
The Difference Between Solid State Relays and Electromagnetic Relays
SSR and EMR are both commonly used electrical control components. Their main difference is that solid state relays are usually based on semiconductor technology and have no mechanical contacts, while electromagnetic relays rely on electromagnetic effects to control the opening and closing of switches. Taken together, SSR have advantages in response speed, durability, and anti-interference capabilities, and are particularly suitable for application scenarios that require fast response and high precision. The EMR performs better in terms of cost and heat dissipation requirements, and is suitable for cost-sensitive applications with low heat dissipation requirements.