1-phase 800VA control transformer on sales, step down 220/380V AC input to 120/48V AC output in 50Hz or 60Hz system. Primary and secondary voltages are customizable and but should note that primary voltage not exceeding 500V, secondary voltage not exceeding 240V.
Specifications
Product Name |
Single phase control transformer |
Product Model |
ATOBK-800VA |
Winding Material |
Enameled copper wire or enameled aluminum wire |
Capacity |
800 VA |
Primary Voltage (VAC) |
110, 120, 208, 220, 230, 240, 380, 400, 480, 110/220, 120/240, 240/480...(Customized) |
Secondary Voltage (VAC) |
6, 12, 24, 36, 48, 120/48, 110/24, 208/36, 220/48, 230/36, 240/120, 120/24/12, 110/36/24, 127/36/6, 208/48/36/24...(Customized) |
Frequency |
50 / 60Hz |
Insulation Level |
F / H |
Withstand Voltage Test |
Primary to secondary 2.5KV/min |
Primary to safety ground 2.5KV/min |
Secondary to safety ground 1.5KV/min |
Insulation Resistance |
Primary to secondary 2500V>100 megohm |
Primary to safety ground 2500V>100 megohm |
Secondary to safety ground 1500V>100 megohm |
Induction Withstand Voltage Test |
125Hz/ 800V/min |
Ground Resistance |
25A<80 milliohm |
Cooling Method |
Natural or air cooling |
Transformation Ratio |
<3% |
Air Carrying Current |
<6% |
Impedance Voltage |
about 6% |
Total Losses |
0.1 |
Efficiency |
80%~99% |
Operating Temperature |
-25℃~40℃ (40℃, 93% RH, 56 days) |
Storage Temperature |
-25℃~100℃ (40℃, 93% RH, 56 days) |
Certificate |
CE, ISO |
Warranty |
12 months |
Size |
Overall size: 150*135*155mm, Hold distance for installation: 120*115mm, Installation hold: 12*7mm |
Weight |
13kg |
Schematic diagram illustration
Control transformer dimension
Overall size (mm) |
Hole distance for installation (mm) |
Installation hole (mm) K x J |
B |
E |
D |
A |
C |
150 |
135 |
155 |
120 |
115 |
12 x 7 |
Tips:
The control transformer is a kind of small dry-type transformer, which is often used as the power supply of local lighting, signal lamp or indicator lamp, and as the power supply of control circuit in electrical equipment. Two points should be paid attention to when using the control transformer: One is the power of the transformer, the other is the correct wiring.
1. The total power of the load connected to the secondary side shall not be greater than the power of the control transformer, and short circuit is not allowed. Otherwise, the temperature will be too high, and transformer will be burned if it is serious.
2. The primary and secondary wiring of the control transformer shall not be wrongly connected, especially the primary side wiring. The voltage value of the primary side shall be marked on its terminal. It is not allowed to connect the 380V power line to the 220V terminal, but the 220V power line can be connected to the 380V terminal. At this time, all the output voltage of the secondary side will be reduced by 1.73 times. The secondary side load shall be connected to the corresponding terminal according to its rated voltage, for example, the 6.3V indicator light shall be connected to the 6.3V terminal, the 36V lighting bulb of the machine tool shall be connected to the 36V terminal, and the 127V AC contactor coil of the machine tool shall be connected to the 127V terminal.