5 kVA 100 kV AC DC Hipot Tester

5 out of 5 based on 1 reviews | Write a review
$6,292.28
Hipot tester manufacturer direct sale, 100 kV AC DC hipot tester capacity 5 kVA, 50/60 Hz sine wave, dry testing transformer with a LCD dispaly, can select manual control, automatic control and electric control, single phase, manufacturer direct sales.
*
*
*
SKU: ATO-HTGTB-5100
30-day Returns
Delivery date: 6-12 days

Low price AC DC hipot tester with superior quality, 5 kVA, 5 kV, it is mainly used for the voltage withstand test of polyethylene insulated power cable, digital display control,  flexible and easy to use.

Note: AC leakage current meter is not provided.

Specifications

Model ATO-HTGTB-5100
Capacity 5 kVA
Input Voltage 110V/ 120V/ 220V
Frequency 50Hz/ 60Hz
Output Voltage 100 kV
Current 50 mA
DC Output 140 kV
Phase 1 Phase
Weight (Transformer+Control Box) 90 kg
Cooling Method Dry
Effeciency 90%
Impedance Voltage <12%
Surface Temperature Raising < 55°C
No Load Current < 4%
Output Voltage Waveform Sine Wave
Usage AC DC Hipot Tester
Warranty 12 Months
Temperature environment 0~40°C
Altitude <2000m
Relative Humidity <85%

Packing List

NO. Description Quantity
1 Hipot Test Set (1 Control Box + 5 kVA Dry Transformer) 1
2 Power Supply Cable 1
3 Earth Cable 1
4 Connecting Line 1
5 Fuse 3
6 Rectifying Diode 1
7 User Manual 1

Wiring Diagram

AC hipot test dimension
DC hipot test

Tips: What is The Difference Between Hipot Test and Megger Test?

The hipot test and the megger test is substantially the same wiring. The withstand voltage test or the high voltage hipot test is a 100% line test used to verify the quality and electrical safety characteristics of the product. This type of test is carried out by subjecting the input line of the electrical product to a high voltage for a specified period of time, and the safety mechanism specifies the amount of high pressure for each product type.
The megger test is mainly to measure the equivalent resistance value formed by the related networks between the two end points and the periphery thereof. The megger test refers to the insulation resistance between the two parts of the conductor separated by an insulating material. In order to ensure the safety of electrical equipment operation, a minimum requirement is imposed on the insulation resistance between the conductors of different polarity (different phases) or between the conductor and the casing.
The megger test is measured by an insulation resistance tester (below 10000V) or an insulated shaker (below 2500V). Since the test voltage is relatively low, many insulation defects are not easily found, and the hipot test voltage is high, and it is easy to find high-voltage equipment.

Existing reviews of 5 kVA 100 kV AC DC Hipot Tester
Deep impression
I really need this HV hipot tester. ATO told me that we can receive the hipot tester in about 12 days, but I got the tester on the eighth day, we can use it in advance, our company is very happy and very impressed.
From: Frank | Date: 13/11/2019
Was this review helpful? Yes No (0/0)
Write your review for 5 kVA 100 kV AC DC Hipot Tester
  • Only registered users can write reviews
  • Bad
  • Excellent