3 Pole or 4 pole isolator switch rate current 350A, used for infrequent connection and segmentation circuit and electrical isolation. Good quality and low price, manufacturer direct sale.
In this video, we delve into the world of load break switches, mechanical devices capable of being operated while under load. We'll explore their functionality, applications in electrical systems, and provide a detailed breakdown of their features to equip you with a thorough comprehension of their advantages.
350A Isolator Switch Specifications
Basics |
Model |
ATOHGL-350A |
Pole |
3 Pole/4 Pole |
Weight |
3 Pole |
4.3 kg |
4 Pole |
4.3 kg |
Technical Parameters |
Rated current |
350A |
Rated insulation voltage Ui |
690V |
Dielectric strength |
1890V |
Rated surge-resistant voltage Uimp kV (installed category IV) |
6 |
Rated working current le |
380V |
AC-21 |
315A |
AC-22 |
315A |
AC-23 |
315A |
660V |
AC-21 |
315A |
AC-22 |
315A |
DC-23 |
125A |
220V |
DC-21 |
315A |
DC-22 |
315A |
DC-23 |
315A |
440V |
DC-21 |
315A |
DC-22 |
315A |
DC-23 |
315A |
Motor power P(380V) kW |
380V |
160 kW |
660V |
185 kW |
Rated short-time withstand current lcw (kA rms)0.1s/ 1.0s |
12.5 |
Rated breaking capability Icn (Arms) AC23 380VA |
2520 |
Rated making capacity Icm (Arms) AC23 380V |
3150 |
Rated short-current making capacity Icm' (Kapeak value) |
25.2 |
Mechanical durability (number of cyclic operation) |
10000 |
Electric durability Ue=660V, Rated current |
COSφ=0.95AC21 |
1700 |
COSφ=0.65AC22 |
100 |
COSφ=0.35AC23 |
500 |
Working Environment |
Moment of operation |
1.2 Nm |
Temperature |
-5℃~+55℃ |
Way of working |
Continuously working |
Operating |
Handle |
Installation form |
Vertical |
Altitude |
≤2000m |
Pollution level |
3 |
Overvoltage level |
Ⅲ |
IP level |
IP 20 |
Dimension
Current |
A |
B |
C |
D |
D1 |
E |
ΦL |
J |
K |
N |
P |
R |
S |
U |
ΦX |
Y |
F |
H |
350A/3P |
230 |
240 |
179 |
50 |
137 |
115 |
7 |
210 |
140 |
135 |
65 |
32 |
40 |
206 |
11 |
37 |
95 |
20 |
350A/4P |
290 |
240 |
179 |
520 |
137 |
114 |
7 |
210 |
140 |
135 |
65 |
32 |
40 |
206 |
11 |
37 |
95 |
20 |
Operation Mode
Details
Tip: Precautions for isolator switch operation
1. During the overhaul of electrical equipment, provide an electrical interval and a clearly visible disconnection point to ensure the personal safety of maintenance personnel.
2. Isolating switch cannot be operated with load: it cannot be operated with rated load or large load, load current and short-circuit current cannot be divided or combined, but the circuit with small load and no-load circuit can be operated with arc extinguishing chamber.
3. In general power transmission operation: first close the isolating switch, then close the circuit breaker or load switch; when the isolating switch is powered off: disconnect the circuit breaker or load switch first, and then disconnect the isolating switch.
4. The selection is the same as other electrical equipment, and its rated voltage, rated current, dynamic stable current, thermal stable current, etc. must meet the needs of the use occasion.