110V/120V/220V/230V/240V/415V/440V/480V single phase to 220V/280V/400V/415V/480V three phase converter for sale, cheap price, 30 hp static phase converter, 25 kW, rated current 62.5A, clear LCD display, easy to use, high conversion efficiency and stable output voltage.
Note:
- When the load is a motor, the phase converter should be more than 5~7 times the motor capacity.
- When the load is soft start + motor, the phase converter should be more than 3 times the motor capacity.
- When the load is VFD + motor, the phase converter should be more than 1.5~2 times the motor capacity.
Specification:
Model |
ATO-BZT-25kW |
Isolation Mode |
Low frequency transformer |
Input Voltage |
Optional: 110V/ 120V/ 220V/ 230V/ 240V/ 415V/ 440V/ 480V) single phase 2 wire |
Output Voltage |
Optional: 220V/ 380V/ 400V/ 415V/ 440V/ 480V) 3 phase 4 wire+PE |
Input Current |
76.9A at 230V (Input Current=Power/Input Voltage/1.414) |
Rated Output Power |
30 hp (25 kW) |
Output Waveform |
Pure sine wave |
Output Current |
36.1A at 400V |
Frequnecy |
50Hz or 60Hz |
Power Factor |
1 |
Overload Ability |
150%, 5 Seconds |
Efficiency |
>93% |
Waveform Distortion Rated (THD) |
≤3%(Linear load) |
Dynamic Respond (0 to 100% load) |
5%, ≤50ms |
Display |
LCD |
Running Mode |
Working continously |
Electrical Inslation Properties |
2000Vac, 1 Minute |
Communication Interface |
RS485 (Optional) |
Protection |
Input under voltage, overvoltage, output over-current, short circuit, overheating etc. |
Cooling Method |
Forced air cooling |
Short Circuit Protection |
No automatic recovery, need to restart the machine |
Noise (1 meter) |
≤50dB |
Degree of Protection |
IP20 (indoor) |
Working Altitude |
≤2000m |
Woorking Temperature |
-25~+55°C |
Relative Humidty |
0~90%, Non condensing |
Dimension |
600*700*1080mm |
Weight |
260kg |
Single Phase
Split phase
Details
30 hp Singel Phase to Three Phase Converter Feature
1. Single phase to 3 phase converter input voltage, output voltage, frequency and phase can be customized.
2. Pure sine wave output, transient response is less than 50ms, waveform distortion is minimal, conversion efficiency is high, and output voltage is stable.
3. The static phase converter uses a low frequency transformer to ensure that the input voltage and output voltage are completely electrically isolated to avoid interference.
4. Using SVPWM space vector algorithm, high conversion efficiency, high instantaneous power, low no-load loss, conversion efficiency can reach more than 94%, and no-load loss is small.
5. The output AC power supply is suitable for all types of appliances, power tools, motors, etc. Has a higher driving load capacity.
6. 3 Phase converter has the function of filtering out grid interference and interference at the same time, with stable voltage and frequency power performance, and provides a more stable and pure power supply environment for back-end equipment.
7. Complete output protection function, with output overvoltage, overload, short circuit, overheating, self-diagnostic protection and other protection functions.
8. High conversion efficiency, high instantaneous power and low load loss.
9. Two start modes: step-down start and variable frequency start. Customers can set the startup mode according to the load type. Reduce the use of frequency converters, thereby reducing equipment investment costs, easy wiring and control.
Tips:
If you have a pump, vertical milling machine, drilling machine, lathe, or even a saw or air compressor that not only needs a sigle phase to 3 phase converter, but also wants to control the speed of the motor to fine-tune your application, then VFD is the controller you need.