Applications
2000VA/1600W UPS is an backup power supply to provide emergency power to a load, and it is mainly used in computer, office equipment, test equipment, light system, safe alarm system, ray equipment, medical equipment, copymachine, numerical control machine tools, industrial automation equipment, color and drying equipment, Hi-Fi equipment etc.
2kVA UPS Specification
Basics |
Model |
ATO-BE-2K |
Phase |
Single phase with ground |
Capacity |
2000 VA/1600 W |
Input |
Nominal Voitage |
100/110/115/120/127VAC or 200/208/220/230/240VAC |
Input Voltage Range |
55-150VAC or 110-300 VAC (Based on load at 50%) |
85-140VAC or 160-280VAC (Based on load at 100%) |
Frequency Range |
40Hz-70Hz |
Power Factor |
≥0.99 @ Nominall voltage (100% load) |
Output |
Output Voltage |
100/110/115/120/127VAC or 200/208/220/230/240VAC |
Voltage Regulation |
±1% |
Frequency Range (Synchronized Range) |
47-53Hz or 57-63Hz |
Frequency Range (Batt. Mode) |
50Hz±0.25Hz or 60Hz±0.3Hz |
Current Crest Ratio |
3:1 |
Harmonic Distortion |
≤3% THD (Linear Load) |
≤6% THD (Non-linear Load) |
Transfer Time |
AC Mode to Battery Mode |
Zero |
Inverter to Bypass |
4 ms (Typical) |
Waveform (Batt. Mode) |
Pure Sinewave |
Efficiency |
AC Mode |
88% |
Battery Mode |
87% |
Battery |
Long-run Model |
Battery Type |
Depending on the capacity of external batteries |
Numbers |
4 |
6 |
8 |
Charging Current (max.) |
1A/2A/4A/6A (Adjustable) |
Charging Voltage |
54.7VDC±1% |
82.1VDC±1% |
109.4VDC±1% |
Indicators |
LCD |
Load level, Battery level, AC mode, Battery mode, Bypass mode, and Fault indicators |
Alarm |
Battery Mode |
Sounding every 4 seconds |
Low Battery |
Sounding every second |
Overload |
Sounding twice every second |
Fault |
Continuously sounding |
Physical |
Long-run Model |
Dimension, DxWxH (mm) |
397x145x220 |
Net Weight (kgs) |
6.8 |
Environment |
Humidity |
20-90% RH @ 0-40°C (Non-condensing) |
Noise Level |
Less than 50dB @ 1 Meter |
Management |
Smart RS-232/USB |
Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux and MAC |
Optional SNMP |
Power management from SNMP manager and web browser |
Note:
1. The UPS input/output configuration is 1-phase (L, N, G) like Europe standard, NOT support the split phase (L1, L2 + G) like USA standard.
2. Batteries that work with this UPS are not included, customers need to match lead-acid battery packs on their own, consult us for battery specifications.
3. If you need other output voltage range, please contact us.
Details
- AC input
- Input circuit breaker
- USB communication port
- RS-232 communication port
- SNMP intelligent slot (option)
- External battery connection (only available for L model)
- Output receptacles
Tips: Why we need a UPS (Uninterruptible Power Supply) for computer?
There are at least nine problems in the power grid, interruption of power supply, lightning stroke spike, surge, frequency oscillation, voltage mutation, voltage fluctuation, frequency drift, voltage drop and pulse interference. Therefore, it is necessary to equip a computer with an uninterruptible power supply (UPS) from the perspective of improving the power quality.
In addition, the power supply is not allowed to be interrupted in precise network equipment and communication equipment. It is self-evident to equip UPS battery backup to the network center with the core of server. Even if it is an ordinary computer, its data file and other software value exceeds the hardware value after being used for three months. Therefore, it is really necessary to equip uninterruptible power supply (UPS) to prevent the data loss.