    10 hp (7.5 kW) Soft starter, 15 A, 3ph 220v/400v/480v

    5 out of 5 based on 4 reviews | Write a review
    $352.31
    Favorable price 10 hp soft starter, 7.5 kW 3 phase 220v, 400v, 480v electric motor soft starts, make motor in soft start & soft stop, direct sale from manufacturer.
    SKU: GS-7d5
    30-day Returns
    Free Shipping
    Delivery date: 6-12 days

    10 hp motor soft starter, 7.5 kW three phase 220v, 400v, 480v, 690v for choice.

    Model GS2-7d5 (220v, 240v), GS3-7d5 (380v, 400v, 415v), GS4-7d5 (460v, 480v), GS6-7d5 (575v, 690v).
    Capacity 10 hp (7.5 kw)
    Current

    15 amps at 380/480v, 30 amps at 220v, 11 amps at 690v

    Weight 5 kgs
    Dimension 270*146*160 mm
    Input Voltage Three-phase 220v, 380v, 480v, 690v AC
    Frequency 50Hz/ 60Hz
    Adaptive Motor Squirrel-cage three-phase asynchronous motor
    Starting Times It is recommended not to exceed 20 times per hour.
    485 Communication DB9 interface, male plug, ① is RS485+, ⑥ is RS485-
    Control Mode
    1. Operation panel control.
    2. Operation panel + external control.
    3. External control.
    4. External control + COM control.
    5. Operation panel + external + COM control.
    6. Operation panel + COM control.
    7. COM control.
    8. No start or stop operation.
    Start Mode
    1. Current-limiting to start.
    2. Voltage ramp to start.
    3. Torque control + current-limiting to start.
    4. Torque control + voltage ramp to start.
    5. Current ramp to start.
    6. Voltage current-limiting double closed-loop start.
    Stop Mode
    1. Soft stop.
    2. Free stop.
    Protective Function
    1. Open loop protection for external instantaneous stop terminals.
    2. Over-heat protection for soft starter.
    3. Protection for too long starting time.
    4. Input open phase protection.
    5. Output open phase protection.
    6. Unbalanced three-phase protection.
    7. Starting over current protection.
    8. Running overload protection.
    9. Under voltage protection for power voltage.
    10. Overvoltage protection for power voltage.
    11. Protection for fault parameter setting of the soft starter.
    12. Load short circuit protection.
    13. Auto restart or incorrect wiring protection.
    14. Incorrect wiring protection of external control stop terminals.
    Ambient Place to be used Indoor location with good ventilation free from corrosive gas and conductive dust.
    Altitude Below 1000M. It has to increase the soft starter rate power when the altitude is more than 1000M.
    Temperature -30 +55 oC
    Humidity 90%RH without dew condensation.
    Vibration <0.5G
    Structure Enclosure IP 20
    Cooling Natural wind cooling.

     

    Details

    7.5KW Soft Starters Details

    Tips: Motor soft starter model selection
    In actual working should consider the specific product features and technical parameters and product reliability, and according to the actual usage to choose the soft starter. Here it is necessary to differentiate that motor is frequent start or infrequent start. For the soft starter, in general, if the motor start interval time does not exceed 2 minutes, and 30 times per hour, can be identified as infrequent start. Less than 2 minutes should be considered as frequent start. Fan and pump load generally belong to infrequent start. Mechanical transmission type like belt machine, grinding mill, and others can be considered as infrequent start. If the motor is starter, or electromotor that is equipped for the large machinery equipment needing reversible function, mostly belongs to frequent start.
    Choosing a soft starter for frequent working place should according to the motor starting current. Normal soft starter silicone controlled rectifier current is 2.5 times of motor rated current. Limit the maximum motor starting current is 4.5 times of the rated current. In the infrequent operation can take full advantage of SCR short-term overload capacity. In the conditions of frequent starting, should select increasing the soft starter capacity, according to the different of frequency take 1.2 to 1.5 times of the capacity. At the same time, due to the SCR frequent working and generating a lot of heat, the soft starter must be equipped with mechanical air-cooled to dissipate heat. It is best to put a mechanical air-cooled soft start device for each switchgear, and the switchgear should also be set with mechanical ventilation.

    Soft Starter Works with a Bypass Contactor

    Soft starter works with a bypass contactor saving energy by eliminating thyristor losses during the run. The bypass contactor shunts the current flowing through the soft starter switch circuit to reduce heat accumulation in the soft starter power electronics during motor operation. This provides maximum efficiency and prolongs the life of soft-start switching components because they only work during the start and stop cycles of the motor.

    How to Change the Soft Starter Rated Current

    Existing reviews of 10 hp (7.5 kW) Soft starter, 15 A, 3ph 220v/400v/480v
    What terminals I need to hook into for a start/stop switch on this drive?
    Hello,  I'm wondering what terminals I need to hook into for a start/stop switch on this drive.  I watched the YouTube video but I don't have that 3 position switch. All I have is a start/stop button or an on/off switch. Thanks
    From: wyatt | Date: 26/11/2023
    Was this review helpful? Yes No (0/0)
    ATO Responded
    Please short-circuit terminals 7 and 10 of the soft starter to lead out a wire, short-circuit terminals 8 and 9 to lead out a wire, and connect these two wires to your switch or button.
    When these two wires are closed, the machine will start, and when these two wires are disconnected, the machine will stop.
    One thing I found weird
    I just installed this soft starter. One thing I found weird as well (which sucks) is I ran power through the by pass contacts (1
    From: Glack | Date: 04/04/2023
    Was this review helpful? Yes No (0/0)
    ATO Responded
    1. The bypass contact (1&2) of the soft starter is used to control the coil of the bypass contactor. The rated capacity of the bypass contact (1&2) is only 250V/5A.  The coil voltage of the bypass contactor is also required to be lower than 250V.
    2. Suppose your grid voltage is three-phase 380V, and the bypass contactor coil is 220V, then the voltage of one live wire and one natural wire in the grid (L+N=220V).  You can connect a live wire L in the grid to a terminal A1 of the contactor coil through the bypass contact (1&2), and connect the other end A2 of the contactor coil to the natural wire N.
    3. If the soft starter has burned out, you need to buy another new one, please refer to the link: https://www.ato.com/softstarter
    Could you please provide your motor nameplate to us for further confirmation?
    Can I start your 50hp soft starter remotely with a 120 volt switch?
    Can I start your 50hp soft starter remotely with a 120 volt switch?
    From: Dale | Date: 02/12/2021
    Was this review helpful? Yes No (0/0)
    ATO Responded
    Yes, sure. This soft starter remote control can be done via (wires + switch), therefore, you can use 120V to control a relay, and then control the start and stop of the soft starter through the contact switch of the relay. It is a very simple control method.
    Good product, meets my need
    This 15A soft starter is applied to my 25A motor. I can handle the unit with no trouble. All the parameters are set on the panel by knob potentiometers and dial switch, that is intuitive and accurate. I feel my motor works really much better than before.
    From: Wright | Date: 05/03/2019
    Was this review helpful? Yes No (0/0)
    Load more reviews...
    Write your review for 10 hp (7.5 kW) Soft starter, 15 A, 3ph 220v/400v/480v
    • Only registered users can write reviews
    • Bad
    • Excellent
    Customers who bought this item also bought

    Custom Order

    Pay for custom orders, or extra amount of existing orders.
    Indicate the item specification you pay for, and specify PI / PO number if you have.

    Float Switch Level Sensor, Stainless Steel/ Plastic

    $61.43
    SKU: ATO-ES12010-2A1
    Stainless steel and plastic float switch level sensor is composed magnetic spring switch and floating ball to detecting the position of the liquid level. Vertical mounted, contact power rating 50W.

    Ultrasonic Level Sensor, Output 4-20mA/1-5V/RS485, 0-40M

    $475.98
    SKU: ATO-LEVS-U40M
    Ultrasonic level sensor has high accuracy 0.3%FS and measuring range 0-5m, 0-10m, 0-15m to 0-40m. It also adopts integrated structure and mainly consists of OLED display, waterproof connectors and ultrasonic probe. Ultrasonic level sensor using advanced non-contact ultrasonic measurement technology can be used for liquid/solid/powder level of tapered/spherical tank, tapered feed outlet tank, sewage tank, river, lake, etc. It has optional output signal 4-20mA, RS485, HART, 2 relays or 3 NPN, optional power supply DC 12-16V, DC 24-28V, AC 220V or built-in battery.

    Insertion Electromagnetic Flow Meter, DN100-DN3000

    $1,797.16
    SKU: ATO-FLOW-IEFM
    Reasonable price and high quality insertion type magnetic flow meter for sale online. The medium of insertion magnetic flowmeter is water. Working temperature of insertion electromagnetic flow meter between -20 ℃ and 70 ℃. It often used in petrochemical, electric power, metallurgy and textile.

    100W Brushless DC Motor, 12V/24V, 0.32 Nm

    $178.58
    SKU: ATO-BLDC-100R3
    100W BLDC motor for sales at affordable price. 3 phase electric brushless motor with 3000 rpm rated speed, 0.32 Nm holding torque and peak torque up to 0.96 Nm. Combines with BLDC controller/ gearbox providing higher torque at 12V or 24V DC.